Page 19
Installation
optoNCDT ILR 1183
5.3.2
Profibus
Pin Assignment Profibus IN Assignment Profibus OUT
1
n.c.
power 5 V
2
A
A
3
n.c.
ground
4
B
B
5
screen
screen
For operation via Profibus, other Profibus participants may connect to the 5-pole male connectors (A-cable,
B-cable). The Profibus may terminate or continue at the 5-pole male connector Profibus OUT. Some kind of
termination device must always be provided at the end of the Profibus. Supply voltage for the bus terminator
is available at Profibus-OUT.
5.4
Profibus Interface
5.4.1
ID Number
The sensor has been registered with “PROFIBUS Nutzerorganisation e.V. (PROFIBUS User Organization,
incorporated society) under ID number 09CB
HEX
.
5.4.2
Connecting Conditions
The sensor is prepared for connection to any type of Profibus DP structure. The related Profibus DP Master
must be capable of sending a parameterization telegram. The Master’s own configuring tool (typically config-
uring software) must support representation of the parameters which are contained in the sensor Master file
(GSD file).
5.4.3
GSD File
The GSD file is named ILR809CB.GSD. It includes the two files “ILR1143.dib” and “ILR1143.bmp” which are
necessary for representation of the sensor in the configuring tool. For information regarding integration of
these files, please consult the special documentation parts that relate to the configuring tool.
Summary of Contents for optoNCDT ILR 1183