Page 34
Profibus Interface
optoNCDT ILR 1183
18 ... 19 0
bool
E15 – reflex signal to weak, use target board
1
bool
E16 – reflex signal too strong, use target board
2
bool
E17 – steady light (that means insolation)
3
bool
E18 – only in DX-mode (50 Hz): variance between measured and
precalculated value too great
4
bool
E23 – temperature below – 10 °C (+ 14 °F)
5
bool
E24 – temperature above + 60 °C (+ 140 °F)
6
bool
E31 – wrong EEPROM checksum, hardware error
7
bool
E51 – failure to set avalanche voltage of laser diode; cause: stray
light or hardware error
8
bool
E52 – laser current too strong / defective laser
9
bool
E53 – failure to set one or more parameters in EEPROM (conse-
quence: division by 0)
10
bool
E54 – hardware error (PLL)
11
bool
E55 – hardware error
12
bool
E61 – selected parameter is illegal; invalid command was triggered
13
bool
E62 – 1. hardware error 2. false value for interface communications
(SIO parity error)
14
bool
E63 – SIO overflow
15
bool
E64 – SIO framing error
20 ... 21
word
warnings – unused (=0)
22 ... 23
word
warnings – unused (=0)
24 ... 25
word
profile version (for example 1.1 = 0110 hex)
26 ... 27
word
software version (for example 1.11 = 0111 hex)
28 ... 31
unsigned 32
operating time (of laser), in units of 0.1 hour
32 ... 35
signed 32
offset value (see Chap. 7.6)
36 ... 39
signed 32
manufacture offset – unused (=0)
40 ... 43
unsigned 32
unsigned 32 measuring units per revolution – unused (=0)
44 ... 47
unsigned 32
unsigned 32 measuring range – unused (=0)
48 ... 57
10 byte
10 byte serial number