PROGRAM MODE
CHECK MODE
RUN MODE
Push and hold the SET button.
Change the slide switch to PROGRAM.
Change the slide switch to PROGARM
Change the slide switch to RUN
RUN
PROGRAM
RUN
PROGRAM
SET
PASS
PUSH & HOLD
RUN
PROGRAM
1-2 Switching: Operation mode and Initialization.
Run mode
In this mode the door moves normally.
Check mode
In this mode you can confirm the current settings of parameter. However you cannot change
settings.
Program mode
In this mode you can confirm and change current settings and values. Reset to factory default
settings is also available.
Reset Operation (Factory Default Reset)
If you change some settings by mistake and the door does not move correctly, it is easy to recover
to factory default settings by reset operation.
If you execute reset operation, default factory settings will be reloaded, except for special setting
code “C”, which is included within the basic code group.
At the same time, door stroke data (teaching) is cleared from the memory. Therefore it will be
necessary for the control to relearn the door stroke. A self learning (teaching) operation will
automatically commence after the run mode is selected again. Re-adjustment of settings may be
necessary after reset operation.
If the door weight or door stroke are changed, reset is also required.
How to execute Reset Operation (Factory Default Reset).
Holding both PASS and SET buttons while in Program mode. A beep sound will indicate reset is
successful. (Hold for approx 5 seconds)