2.  Installation Requirements 

– ENSURE: 

 

All  components  have  been  installed  correctly  in  accordance  with  the  installation  manual  and  all 
wiring  has  been  connected  referring  to  EDM  NII  Series  wiring  drawings.  (except  main  cover  and 
activator on the main cover) 

 

The door should be easily moved open and closed by hand without abnormal sounds. 

 

Confirm  that  wires  and  cables  do  not  touch  moving  components  such  as  belt  or  hanger  roller 
assembly. 

 

Run  /  Program  mode  se

lecting  switch  should  be  set  in  ‘Run’  position  to  execute  the  teaching 

operation. 
 

3.  Executing Self learning cycle (TEACHING) 

 

Self learning cycle is executed after installation by turning the mains power switch ON for the first 

time. The door will close (*1) to the full closed position, then open automatically (*2) at slow speed. 

When the door has reached to the full open position, the first stage of the teaching cycle is complete 

and the door will start to close at normal speed. 

 

Activate the sensor and check the door will open smoothly. Here, the breaking position is located at 

the center of doorway is automatically calculated. After a few cycles, the operator will optimize the 

braking point taking into consideration operating speed, breaking force and door weight. 

 

Teaching  data  such  as  the  door  stroke and braking  position  will  be  stored  within  the  control  unit, 

even if the mains power is OFF. 

 

Once the mains power is turned ON, the stored data will be reloaded when the door reaches the 

fully closed or open end position. 

 

Motor  torque  value  during  teaching  mode  will  be  the  same  as  factory  default  values.  Or  if 

re-teaching, will be the same as basic setting code values held within the memory. For max torque 

when teaching switch application code ‘dL’ OFF. 

 

(*1) If the door does not close, check Red LED (sensor indicator) is ON. If Red LED is ON, this means 

there is  an  activation  signal  being  received. Once  reaching  the  full open  position,  after  the  sensor 

signal is off and the hold open time is complete, the door will close and return to full closed position.   

 

(*2)  If  teaching  stroke 

setting  (Basic  Setting  Code  ‘b’)  is  changed  from  factory  default  setting.  The 

teaching function will not be automatic. It is required to be activated by a sensor or test button, after 

door  has  reached  full  closed  position.  The  door  will  open  at  programmed  teaching  speed.  On 

Activation of sensor before fully closed, the door will re-open at slow speed. 

 

 

 

 

 

 

 

 

 

Summary of Contents for EDM NII Series

Page 1: ...I Series Control Manual MICOM AUTODOOR Automatic Sliding Door Operator Model EDM NII Series Effective from Lot No 1206 Original Instructions OPERATION MANUAL Date June 2012 OSAKA JAPAN www micomautodo...

Page 2: ...pt to modify repair or alter any parts within the control box Do not remove screws and bolts from the internal structure of the Control Unit The failure to comply will result in loss of warranty Insta...

Page 3: ...ally between 3 to 5 times Known as teaching or self learning mode Please note these learning cycles are performed at LOW speed Keep clear of the entrance and doors Ensure that no pedestrians pass thro...

Page 4: ...4 Opening Closing Break Force 9 5 1 5 Opening Closing Force Torque 9 5 1 6 Pressing Force 9 5 1 7 Partial Open Half Open 10 5 1 8 Teaching Stroke 10 5 1 9 Other Function Use 10 5 2 Applied Settings 11...

Page 5: ...de Activation Signal for Test open cycle Program mode Changes current setting code or value 4 LED DISPLAY LED 1 2 When switched to Run mode Displays Cycle Counter Stepped in 10 000 Cycles Program mode...

Page 6: ...stake and the door does not move correctly it is easy to recover to factory default settings by reset operation If you execute reset operation default factory settings will be reloaded except for spec...

Page 7: ...few cycles the operator will optimize the braking point taking into consideration operating speed breaking force and door weight Teaching data such as the door stroke and braking position will be stor...

Page 8: ...irection is set by a DIP Switch on the Control Box CB DIP Switch 1 is for determination of open direction As shown DIP Switch 2 and 3 shall be in OFF position SW 1 2 3 ON Up LEFT OFF Down RIGHT DOUBLE...

Page 9: ...ushion Low Speed Basic setting code LED1 2 6 Opening cushion low speed is adjusted in 16 steps from 0 to F by basic setting code 2 Closing cushion low speed is adjusted in 16 steps from 0 to F by basi...

Page 10: ...ull speed If you set at 1 or higher the door will open at normal speed performing the teaching stroke Note that the teaching stroke MUST not exceed more than 70 of total door stroke If you set at 0 de...

Page 11: ...main sensor SS the door will begin to open Upon a pedestrian standing in front of the leading edge a sensor mounted above this area called side screen safety AS will be activated SS and AS signals ar...

Page 12: ...132 times Electro Special Setting Setting Code 0 C Value Setting Code Value Indication order Error counter Upper 2 digit Error code Error counter Lower 2 digit Pass Internal Reset Error history count...

Page 13: ...ad situation IMPORTANT To return back to normal operation 1 To recycle the doors and reset Error protection failsafe mode switch mains power Off On 2 Please look to solve the cause of error E1 and E2...

Page 14: ...9 4 Open Force 4 4 0 9 5 Close High Speed 5 5 0 F 6 Close Low Speed 6 4 0 F 7 Close Break Force 7 4 0 9 8 Close Force 8 4 0 9 9 Pressing Force 9 1 0 4 A Partial open width A 3 0 9 B Teaching stroke b...

Page 15: ...lectromagnetic Lock is detected Set to OFF when the Electromagnetic Lock is NOT connected YES NO d 4 BATTERY SYSTEM Emergency system Set on with Battery Close system BC or Set on when you need to CLOS...

Page 16: ...position Door will not move While door is moving AS signal ignored For AS signal Setting C 9 must be selected DOOR FIX d H DOOR PRESS WHEN ES Set OFF in case breakout panic door is in use with ES sig...

Page 17: ...rror detection time P5 00 50 Error detection threshold during high speed closing cycle P6 00 10 Error detection threshold during low speed closing cycle P7 00 50 Low speed travel range during closing...

Page 18: ...contact CODE SETTING AS SB PS ES CODE SETTING AS SB PS ES PE 00 PE 08 NC PE 01 NC PE 09 NC NC PE 02 NC PE 0A NC NC PE 03 NC NC PE 0b NC NC NC PE 04 NC PE 0C NC NC PE 05 NC NC PE 0D NC NC NC PE 06 NC N...

Page 19: ...power OFF and ON Re teach will be performed E1 Open error 1 short sound between long sounds Obstruction during the opening cycle Door is physically locked E2 Close error 2 short sound between long so...

Page 20: ...amed OUT board or with NII G type controller which includes another extension board named I O board Each board has a unique board address setting by DIP switch which means you can select each signal f...

Page 21: ...ority door in the interlock mode Open A Output OA Make relay contact at full open position OE SIGNAL RELAY A Open B Output OB Break relay contact at full open position OE SIGNAL RELAY B Close A Output...

Page 22: ...OP CE LCS PBH OSE ES SPC IL NT AS EO PR RS1 RS1 OE OE OE OE CE CE CE CE 6 4 Corresponding table between Board address and DIP switch Output board OUT Input Output board I O Board address 0 1 2 3 4 5 6...

Page 23: ...Tower West Umeda Skybuilding 1 30 Oyodonaka 1 Chome Kita ku Osaka 531 0076 Japan TEL 0081 6 6 454 9721 FAX 0081 6 6 454 9726 E MAIL info micomautodoor com MICOM Autodoor Europe 2 nd Flr Dobson House...

Reviews: