6-2 Description of signals of I/O board
Board
Address
Signal name
Symbol
Description
4
Opening brake
LOB
Limit switch to designate the position to retard opening
Closing brake
LCB
Limit switch to designate the position to retard closing
Half-opening brake
LHO
Limit switch to designate the position to retard half-opening
Closing stop
LCS
Limit switch to designate the position to stop closing
LS mode
SPC
Enable Limit switch mode oparation
Emergency Open
EO
Open for 15 seconds at a low speed
Open A (Output)
OA
Make relay contact at full open position. OE SIGNAL RELAY
A
Open B (Output)
OB
Break relay contact at full open position. OE SIGNAL RELAY
B
Close A (Output)
CA
Make relay contact at full closed position. CE SIGNAL RELAY
B
Close B (Output)
CB
Break relay contact at full closed position. CE SIGNAL RELAY
B
5
Push Button for Opening
PBO
Open and hold open until the other push button is depressed
Push Button for Closeing.
PBC
Close
Push Button for Stop.
PBS
Stop and stay until the other push button is depressed.
Push Button for Half opeining. PBH
Partial open and stay at the designated position.
InterLock
IL
Enable opening in the interlock mode.
Priority
PR
Designate the priority door in the interlock mode.
Open A (Output)
OA
Make relay contact at full open position. OE SIGNAL RELAY
A
Open B (Output)
OB
Break relay contact at full open position. OE SIGNAL RELAY
B
Close A (Output)
CA
Make relay contact at full closed position. CE SIGNAL RELAY
B
Close B (Output)
CB
Break relay contact at full closed position. CE SIGNAL RELAY
B
6
Panic Switch
PS
Emergency operation / Panic Open or Close
Ratchet Switch
RS
Hold-open/Close switchable
Half-open Ratchet switch
HRS
Partial open and hold open until next signal.
Outer Sensor Enable
OSE
Enable the outer sensor in the security mode.
Ratchet Switch 1
RS1
Open/Close/Stop in the middle of opening switchable
Open A (Output)
OA
Make relay contact at full open position. OE SIGNAL RELAY
A
Open B (Output)
OB
Break relay contact at full open position. OE SIGNAL RELAY
B
Close A (Output)
CA
Make relay contact at full closed position. CE SIGNAL RELAY
B
Close B (Output)
CB
Break relay contact at full closed position. CE SIGNAL RELAY
B
7
(Default)
Panic Switch
PS
Emergency operation / Panic Open or Close
Ratchet Switch
RS
Partial open and hold open until next activation signal.
Half-open Switch
HS
Partial open
Emergency stop Switch
ES
Emergency Stop
Anzen Switch
AS
Side Safety Screen
Ratchet Switch 1
RS1
Open/Close/Stop in the middle of opening switchable
Open A (Output)
OA
Make relay contact at full open position. OE SIGNAL RELAY
A