5. Control Box settings 2 (Software settings for internal parameters)
For standard doors it is possible to operate with default settings. A standard door is a single leaf door
that weights approx 45kg to 90kg. However attention must be paid to the DIP Switch setting for open
direction.
Heavier door(s) that exceed standard door limits in weight and size will require adjustment of parameters
in order to optimize door operation.
5-1 Basic Settings
According to door operation requirements, door parameters can be changed as follows:
5-1-1 Hold Open time
Basic setting code (LED1)
‘0’
Hold open time is adjusted in 16 steps from ‘0 to F’, by basic setting code ‘0’.
Value
0
1
2
3
4
5
6
7
8
9
A
b
C
d
E
F
time(sec)
0
1
2
3
4
5
6
7
8
9
10
20
30
40
50
60
5-1-2 Opening/Closing Speed
Basic setting code (LED1)
‘1&5’
Opening speed is
adjusted in 16 steps from ‘0 to F’ by basic setting code ‘1’.
Closing speed is adjusted in 16 steps from ‘0 to F’ by basic setting code ‘5’.
5-1-3 Opening/Closing Cushion (Low) Speed
Basic setting code (LED1)
‘2&6’
Opening cushion (low) speed is adjusted in 16
steps from ‘0 to F’ by basic setting code ‘2’.
Closing cushion (low) speed is adjusted in 16 steps from ‘0 to F’ by basic setting code ‘6’.
5-1-4 Opening/Closing Break Force
Basic setting code (LED1)
‘3&7’
Opening break force is adjusted in 10 steps from ‘0 to 9’ by basic setting code ‘3’.
Closing break force is adjusted in 10 steps from ‘0 to 9’ by basic setting code ‘7’.
*As default break force is set for light weight doors and/or single leaf door, check and confirm that the
break force is correct for your door(s).
5-1-5 Opening/Closing Force (Torque)
Basic setting code (LED1)
‘4&8’
Opening force is adjusted in 10 steps from ‘0 to 9’ by basic setting code ‘4’.
Closing force is adjusted in 10 steps from ‘0 to 9’ by basic setting code ‘8’.
*If using narrow and/or light weight door(s). To prevent jumping when the doors start to move, set
Open/Close Force (torque) value lower. Normal doors require setting minimum ‘3’ and above.
5-1-6 Pressing Force
Basic setting code (LED1)
‘9’
Pressing force is adjusted in 5 steps fro
m ‘0 to 4’ by basic setting code ‘9’.
If you select 0, pressing function is disabled. (No pressing force)