1. Identifying Control Box Features and Modes.
1-1 Main Control Box NII Series
1
Green LED (Light Emitted Diode)
1. Power indicator
2.
When in ‘program mode’ – Green LED flashes
6
LED Indicator of Extension Board (If included)
Green: Input-Output board / Red: Output board
2
Red LED (Light Emitted Diode)
1. Sensor indicator / activation
2. Program setting. Application ON/OFF indicator
7
Run / Program Switch
Change into Program mode from Run Mode.
*Additional operation required
3
2P connector - Factory test use only.
8
Test Button / Pass Button - When switched to:
Rum mode: Activation Signal for Test open cycle
Program mode: Changes current setting code or value
4
LED DISPLAY (LED 1 & 2)
– When switched to:
Run mode: Displays Cycle Counter (Stepped in 10,000 Cycles)
Program mode: Displays Setting code and Value
* During start up: Displays optional extension board number, if included
* In case of Error: Displays Error code
9
SET button
– When switched to:
Program mode: Change or accept setting value
Run mode: Press and hold for 5 sec. Full Cycle counter will
appear
5
Buzzer
If Buzzer setting is ON will beep to indicate: Error, Emergency open or close
mode, Battery operation mode. (ref. d0 setting code)
10
DIP switch
Switch1: Setting for open direction (Do not adjust Switch 2 & 3)
Switch2&3: Must be in OFF position (Factory test use only)