Micom Autodoor EDM NII Series Operation Manual Download Page 22

 

 

Open B      (Output) 

OB 

Break relay contact at full open position. OE SIGNAL RELAY 

Close A      (Output) 

CA 

Make relay contact at full closed position. CE SIGNAL RELAY 

Close B      (Output) 

CB 

Break relay contact at full closed position. CE SIGNAL RELAY 

Refer to the standard wiring diagrams for further information. 

 

6-3    Signal layout on the extension boards. 

Output board    [OUT] 

Input Output board      [I/O] 

 

Board address 

OPN 

WA 

SBO 

 

LOB 

PBO 

PS 

PS 

 

CLS 

ERR 

UL 

 

LCB 

PBC 

RS 

RS 

 

STP 

OE 

 

LHO 

PBS 

HRS 

HS 

 

HOP 

CE 

 

LCS 

PBH 

OSE 

ES 

 

 

 

 

 

SPC 

IL 

NT 

AS 

 

 

 

 

 

EO 

PR 

RS1 

RS1 

 

 

 

 

 

OE 

OE 

OE 

OE 

 

 

 

 

 

CE 

CE 

CE 

CE 

 

 
6-4    Corresponding table between Board address and DIP switch 

 

Output board    [OUT] 

Input Output board      [I/O] 

Board address 

DIP switch1 

OFF 

ON 

OFF 

ON 

OFF 

ON 

OFF 

ON 

DIP switch2 

OFF 

OFF 

ON 

ON 

OFF 

OFF 

ON 

ON 

 

Default 

 

 

 

 

 

 

Default 

Note: Above chart is printed on the each extension board, such as shown below. 

DIP Switch is on the expansion board.    (To change the setting, remove lid) 

 

OFF

ON

0

1

2

3

OUT

1
2

ADDRESS

DIPSW

OFF

OFF

ON

ON

ON

OFF

O
F
F

LED (Red)

OFF

ON

4

5

6

7

I/O

1
2

ADDRESS

DIPSW

OFF

OFF

ON

ON

ON

OFF

LED(Green)

O
F
F

 

 

 

7.  Adjustment of sensor 

Refer to a sensor instruction manual for wiring and adjusting sensor. 

 

 

 

 

Summary of Contents for EDM NII Series

Page 1: ...I Series Control Manual MICOM AUTODOOR Automatic Sliding Door Operator Model EDM NII Series Effective from Lot No 1206 Original Instructions OPERATION MANUAL Date June 2012 OSAKA JAPAN www micomautodo...

Page 2: ...pt to modify repair or alter any parts within the control box Do not remove screws and bolts from the internal structure of the Control Unit The failure to comply will result in loss of warranty Insta...

Page 3: ...ally between 3 to 5 times Known as teaching or self learning mode Please note these learning cycles are performed at LOW speed Keep clear of the entrance and doors Ensure that no pedestrians pass thro...

Page 4: ...4 Opening Closing Break Force 9 5 1 5 Opening Closing Force Torque 9 5 1 6 Pressing Force 9 5 1 7 Partial Open Half Open 10 5 1 8 Teaching Stroke 10 5 1 9 Other Function Use 10 5 2 Applied Settings 11...

Page 5: ...de Activation Signal for Test open cycle Program mode Changes current setting code or value 4 LED DISPLAY LED 1 2 When switched to Run mode Displays Cycle Counter Stepped in 10 000 Cycles Program mode...

Page 6: ...stake and the door does not move correctly it is easy to recover to factory default settings by reset operation If you execute reset operation default factory settings will be reloaded except for spec...

Page 7: ...few cycles the operator will optimize the braking point taking into consideration operating speed breaking force and door weight Teaching data such as the door stroke and braking position will be stor...

Page 8: ...irection is set by a DIP Switch on the Control Box CB DIP Switch 1 is for determination of open direction As shown DIP Switch 2 and 3 shall be in OFF position SW 1 2 3 ON Up LEFT OFF Down RIGHT DOUBLE...

Page 9: ...ushion Low Speed Basic setting code LED1 2 6 Opening cushion low speed is adjusted in 16 steps from 0 to F by basic setting code 2 Closing cushion low speed is adjusted in 16 steps from 0 to F by basi...

Page 10: ...ull speed If you set at 1 or higher the door will open at normal speed performing the teaching stroke Note that the teaching stroke MUST not exceed more than 70 of total door stroke If you set at 0 de...

Page 11: ...main sensor SS the door will begin to open Upon a pedestrian standing in front of the leading edge a sensor mounted above this area called side screen safety AS will be activated SS and AS signals ar...

Page 12: ...132 times Electro Special Setting Setting Code 0 C Value Setting Code Value Indication order Error counter Upper 2 digit Error code Error counter Lower 2 digit Pass Internal Reset Error history count...

Page 13: ...ad situation IMPORTANT To return back to normal operation 1 To recycle the doors and reset Error protection failsafe mode switch mains power Off On 2 Please look to solve the cause of error E1 and E2...

Page 14: ...9 4 Open Force 4 4 0 9 5 Close High Speed 5 5 0 F 6 Close Low Speed 6 4 0 F 7 Close Break Force 7 4 0 9 8 Close Force 8 4 0 9 9 Pressing Force 9 1 0 4 A Partial open width A 3 0 9 B Teaching stroke b...

Page 15: ...lectromagnetic Lock is detected Set to OFF when the Electromagnetic Lock is NOT connected YES NO d 4 BATTERY SYSTEM Emergency system Set on with Battery Close system BC or Set on when you need to CLOS...

Page 16: ...position Door will not move While door is moving AS signal ignored For AS signal Setting C 9 must be selected DOOR FIX d H DOOR PRESS WHEN ES Set OFF in case breakout panic door is in use with ES sig...

Page 17: ...rror detection time P5 00 50 Error detection threshold during high speed closing cycle P6 00 10 Error detection threshold during low speed closing cycle P7 00 50 Low speed travel range during closing...

Page 18: ...contact CODE SETTING AS SB PS ES CODE SETTING AS SB PS ES PE 00 PE 08 NC PE 01 NC PE 09 NC NC PE 02 NC PE 0A NC NC PE 03 NC NC PE 0b NC NC NC PE 04 NC PE 0C NC NC PE 05 NC NC PE 0D NC NC NC PE 06 NC N...

Page 19: ...power OFF and ON Re teach will be performed E1 Open error 1 short sound between long sounds Obstruction during the opening cycle Door is physically locked E2 Close error 2 short sound between long so...

Page 20: ...amed OUT board or with NII G type controller which includes another extension board named I O board Each board has a unique board address setting by DIP switch which means you can select each signal f...

Page 21: ...ority door in the interlock mode Open A Output OA Make relay contact at full open position OE SIGNAL RELAY A Open B Output OB Break relay contact at full open position OE SIGNAL RELAY B Close A Output...

Page 22: ...OP CE LCS PBH OSE ES SPC IL NT AS EO PR RS1 RS1 OE OE OE OE CE CE CE CE 6 4 Corresponding table between Board address and DIP switch Output board OUT Input Output board I O Board address 0 1 2 3 4 5 6...

Page 23: ...Tower West Umeda Skybuilding 1 30 Oyodonaka 1 Chome Kita ku Osaka 531 0076 Japan TEL 0081 6 6 454 9721 FAX 0081 6 6 454 9726 E MAIL info micomautodoor com MICOM Autodoor Europe 2 nd Flr Dobson House...

Reviews: