C-3 = EMS - Battery Back Up.
EMS Battery back-up allows normal operation (open/close) for as long as the battery has charge. Open
and close speed are steady, however speed may be affected.
C-7 = PS - Panic Signal.
Panic Signal once activated, overrides any another signal and will reverse the door to full open from
any position. Panic Signal is commonly used in case of Fire Alarm input or together with our battery
system.
C-8 = RS - Ratchet Function.
Ratchet Function (Flip-Flop) allows the user to operate the door by pressing an activation button once
to open the door. The door will not close and remain in the hold open positions for an infinite amount of
time. The user can close the door by pressing the activation button again, and then the door will return
to the closed position.
C-9 = AS - Side Screen Safety Function.
Side Screen safety input allows the use of additional sensors to protect the area in front of the door/s
leading edge when opening. For example, following activation of the main sensor (SS), the door will
begin to open. Upon a pedestrian standing in front of the leading edge, a sensor mounted above this
area, called side screen safety (AS) will be activated. SS and AS signals are now both ON, the door will
creep at low speed until the AS input goes OFF. Once AS is OFF, the door will resume normal opening
speed.
C-A = HS
– Half Open Function.
HS is a special half open function used as a standalone half open signal, for use in factory locations for
example. HS is used when you need to combine Full Open and Half Open functions. In case a large
cargo is to pass through a large entrance, the doors are operated by SS signal. This gives full open.
Incase pedestrian are to pass through the same entrance, use of a push button connected to HS can
be used and the door will open partially, in order to allow pedestrians through without opening fully.
Standard Half open HO signal is independent of HS signal.
5-2 Applied Settings
Changing applied setting might be helpful for some special operation applications
To use applied settings, NII-G (I/O Board
– Input/ Output) or NII-R (Output Board) type control box may
be required in some cases. Please enquiry for more details.