Wall formwork
Mammut 350
Height-extended 90° outside corner
Height-extended outside
corner
Pouring heights of 4.25 m (or
higher) require the number of
assembly locks and alignment
rails shown in Table 22.3.
The alignment rails must be
attached to the panels with two
flange screws 18. Always start
attaching the alignment rails
at the bottom multi-function
profile, i.e. the first alignment
rail must be attached to the
bottom multifunction profile of
the bottom outside corner. Note
that the alignment rails must
cover the next panel joint and
be bolted at the corners (Fig-
ures 22.1 and 22.2).
Height-extended outside corner
Pouring height
[cm]
Number of alignment rails (from bottom to top)
Number of
M assembly
locks
Wall thickness [cm]
0–25
26–50
51–75
76–100
101–125
425
—
—
—
—
1
10
475
—
—
—
1
1
10
500
—
—
—
1
1
10
550
—
—
—
1
1
11
600
—
—
—
2
2
12
650
—
—
1
2
2
13
700
1
1
1
2
2
14
750
1
1
1
2
2
15
800
1
1
1
2
2
16
850
2
2
2
3
3
17
900
2
2
2
3
3
18
950
2
2
2
3
3
19
Table 22.3
Fig. 22.1
Fig. 22.2
Flange screw
18
Alignment rails
bolted at corner
M350-22
Technical Instruction Manual / Status November 2018