A 1632
eMobility Analyser
Single tests
17
Measurement procedure
Connect the charging cable /station to the eMobility Analyser (see test circuits above).
Select Diagnostic test
– EV simulator on the master instrument.
Set test parameters on the master instrument.
Check that the eMobility Analyser is in Remote mode (Bluetooth communication between
eMobility Analyser and the master instrument is established).
Carry out the Diagnostic test.
Manually set status of the test (Optional).
Save results (optional).
For information about test parameters and displayed results refer to Instruction manual of the
master instrument.
5.3.2 Autonomous mode
The eMobility
Analyser test condition can be set with the switches and keys on the analyser’s
front panel. Only Mode 2 single and 3-phase charging cables can be tested in this mode.
Figure 5.9: Diagnostic test - EVsimulator test connection to the Mode 2 charging cables -
Autonomous mode
5.4 Diagnostic test
– Monitor
This test monitors and analyses the CP signal and voltages between the charging cable / station
and the electrical vehicle. For this test a monitor adapter cable (A 1631) is needed
The test is performed in combination with eMobility Analyser and an external (master)
instrument. The results are transmitted via Bluetooth and displayed on the master instrument.