A 1632
eMobility Analyser
Technical specifications
22
8
Technical specifications
8.1 Diagnostic test (EVSE)
U1N, U2N, U3N
– Mains voltage
Measuring range (V)
Resolution (V)
Accuracy
0 ... 440
1
(2 % of r 2 digits)
Nominal frequency range ....................... 0 Hz, 14 Hz ... 500 Hz
Field
– Phase rotation
Result displayed ..................................... 1.2.3 or 3.2.1
UCP+, UCP-
– Voltage
Measuring range (V)
Resolution (V)
Accuracy
-19.9 V ...19.9 V
0.1
(2 % of r 2 digits)
Result..................................................... positive, negative peak value (
8 μs interval)
Freq
–
Frequency
Measuring range (Hz)
Resolution (Hz)
Accuracy
500.0 ... 1500.0
0.1
1 % of reading
D
–
Duty cycle
Measuring range (%)
Resolution (%)
Accuracy
0.1
… 99.9
0.1
10 digits
Ievse
–
Charging current available by charging cable / EVSE
Displayed range (A)
Resolution (A)
Accuracy
0.0 … 99.9
0.1
Calculated value*
*According to Table A.8 in IEC/EN 61851-1
toff
– Disconnection time
Measuring range (ms)
Resolution (ms)
Accuracy
0
… 399
1
(1 % of r 5 digit)
Note:
For t
off