A 1632
eMobility Analyser
Technical specifications
23
8.2 PP, CP simulator
PP simulation
State
Resistance
N.C.
> 300 kΩ
13 A
1.5 kΩ ± 1.5 %
20 A
680 Ω ± 1.5 %
32 A
220 Ω ± 1.5 %
63 A
100
Ω ± 1.5 %
80 A
56 Ω ± 5 %
CP simulation
State
Resistance
A
> 300 kΩ
B
2.74 kΩ ± 1.5 %
C
882 Ω ± 1.5 %
D
246 Ω ± 1.5 %
8.3 System state
Possible systems states (measured interpreted by the Analyser*)
State
Meaning
A1
no EV connected
A2
no EV connected / PWM
B1
EV connected
B2
EV connected / PWM
C1
EV charged
C2
EV charged / PWM
D1
EV charged and ventilation
D2
EV charged and ventilation / PWM
E
Error
F
Failure
Invalid
CP signal can’t be classified
* According to Table A.4 in IEC/EN 61851-1.
If more states are displayed as result, all states can be considered as valid according to IEC/EN