A 1632
eMobility Analyser
Single tests
16
Measurement procedure
Connect the charging cable /station to the eMobility Analyser (see test circuits above).
Select the measurement or inspection on the safety tester.
Set test parameters / limits of the selected measurement on the test instrument.
Put the charging cable / station into proper operating mode by setting the eMobility Analyser.
Connect the instrument test leads to the Analyser sockets (optional), see test circuits above
and Instruction manual of test instrument.
Carry out the measurement or inspection.
Save results (optional).
5.3 Diagnostic test
– EV simulator
This test is intended for simulation of an electrical vehicle with eMobility Analyser. The CP and
PP states can be set in order to put the charging cable/ station into proper operation mode. The
CP signal is analysed and the presence of voltage at the output of the charging cable / station is
monitored.
5.3.1 Remote connection
The test is performed in combination with an external (master) instrument. The results are
transmitted via Bluetooth communication link and displayed on the master instrument.
Test connections
Figure 5.7: Diagnostic test - EV simulator test connection to the Mode 3 EVSE
Figure 5.8: Diagnostic test - EV simulator test connection to the Mode 2 charging cable - Remote
connection