Saved States
button: This button allows the user to either save, load, or erase a switch
configuration. Saving a state allows the user to use the same switch set up at a later time.
When the
Save
button is clicked, a prompt will appear. The user selects a number, 0 through
127, from this field. Click
OK
to save the current state as the state number entered. To load or
erase a saved state, simply click on the
Load
or
Erase
button, select the desired state number
from the dialog box that appears, and then click
OK
.
Path
button: This button opens the
Path
configuration window. From this window, the user
can define channel-to-channel relationships by entering the desired path in the New Path text
box using the formatting described in the
Help
discussion. Clicking on the
Connect
button
will close the relays required to establish the
Path
. Once defined, the path can be found in the
Established Paths
text box. The path can then be established or removed by using the
Reconnect
and
Disconnect
buttons. The
Details
button provides information about the path
selected in the
Established Paths
text box.
F
IGURE
7-12:
P
ATH
C
ONFIGURATION
W
INDOW
Reset
button: This button clears the existing state of the relays and places them back in their
default positions.
Device Info
If the
Device Info
tab is clicked, information regarding the selected instrument will be displayed
including the versions of the SFP, firmware, hardware, and configuration.
F
IGURE
7-13:
D
EVICE
I
NFORMATION
W
EB
P
AGE
Summary of Contents for EX1200A SERIES
Page 32: ......
Page 50: ...VTI Instruments Corp 50 EX1200A Series Preparation for Use...
Page 63: ...www vtiinstruments com EX1200A Series Preparation for Use 63...
Page 64: ......
Page 72: ......
Page 106: ...VTI Instruments Corp 106 EX1200A Triggering...
Page 108: ...VTI Instruments Corp 108 EX1200A Triggering FIGURE 6 1 EX1200A SERIES TRIGGER MODEL...
Page 142: ...VTI Instruments Corp 142 EX1200A Web Page Operation...
Page 144: ...VTI Instruments Corp 144 EX1200A Series Programming...
Page 154: ......
Page 160: ......