INSTRUCTION MANUAL
– BALER Z562
41
The tank
Carry out routine checks and replenish the oil in the tank of the automatic chain-
lubrication system. Procedure
•
Open the left-hand-side protective guard
•
Unscrew the cap, refill oil and re-tighten the cap. The tank
volume is 3 litres.
Figure 54.
The oil tank of the automatic chain-lubrication system
Filter replacement (once a year)
The filter is in the oil tank. It is recommended to replace it once a year. Procedure.
•
Open the left-hand side guard
•
Drain the tank
•
Open the automatic lubrication oil tank
•
Replace the filter
•
Replenish the oil in the tank
•
Close the oil tank,
•
Close the cover.
Always use clean oils. Simple mineral oils should be used.
Recommended oils
•
SAE30 - for low-temperature applications,
•
SAE90 - for use in warm environments.
Cap