TS790+ & TS900+ Installation Manual
Engineer’s Menu 3
49
Location Text
This option allows the engineer to program a 32
character location message. When “Engineers
menu 1" is selected the engineer can view this
message. This can be used to provide the
location details for the control panel, e.g., ”C P
located in reception area", thus assisting service
engineers unfamiliar with the site.
Printer Header
This option allows the installation engineer to
program a 32 character printer header
message. This is printed whenever a system or
log printout is taken from the system. This can
be used as a site reference, e.g., “ABC
Company Job No123456".
Part Set Banner
The part set banner is a 16 character message
displayed on the top line of the display
whenever the system is part set. If the message
is left blank the top line of the display will show
the wards that are set. If the message is
programmed the top line of the display will
show the message, e.g., “System Part-Set”.
Custom Text Menu
XNode Outputs
[3.8]
This option allows the engineer to program the
two outputs on each XNode. Each output can
be programmed to any of the output types, see
page 25.
XNode Outputs Flowchart
Built In Tests
[3.9]
The TS790+/TS900+ system has the following
diagnostic routines:
Current Consumption
This option displays the total current
consumption for the system on mains power
accurate to
±
50mA. Note that the system
cannot display battery only current
consumption.
System Current Flowchart