Engineer’s Menu 2
TS790+ & TS900+ Installation Manual
40
View Circuits
[2.1]
Each detection circuit may be viewed to
ascertain its status. The circuit status conditions
and resistance are shown below:
Status
Response
Normal
Min.
Max.
Healthy
None
2.2 K
W
54
W
4.1K
W
Active
Alarm
6.9 K
W
4.1 K
W
54 K
W
Tamper
Tamper
¥
54 K
W
¥
Shorted
Alarm
0
W
0
W
53
W
View Circuits Flowchart
Set System Time
[2.2]
The system time is displayed in a 24hr format on
all remote keypads and is also used to time
stamp events in the system event log.
Set System Time Flowchart
Set System Date
[2.3]
The system date is displayed in a
day/date/month format on LCD remote
keypads. it is also used to provide date stamps
for events in the system log.
Set System Date Flowchart
Change Passcode
[2.4]
This option allows the engineer to change their
passcode. The default passcode is 1234 but
the installation engineer should change this to
their own personal 4 digit passcode.
Change Passcode Flowchart