System Installation
TS790+ & TS900+ Installation Manual
6
Control Panel Installation
Proceed as follows:
1. Open the control panel by removing the
three screws from the front cover. Remove
the cover by sliding it up slightly to
disengage the bottom clip.
2 Note the position of the cable entries as
follows:
(a) Ten 20mm cable entries for detection,
alarm and remote keypad cables.
(b) A 20mm cable entry for mains (240V)
below the mains input terminal block.
¨
The mains cable must enter the control
panel through its own cable entry and
must not be mixed with other cables.
3. Hold the control panel back box in the required
position (keyhole to the top) and mark the centre
of the keyhole position. Remove the back box,
drill and plug the hole.
Figure 5. TS790+ & TS900+ Control Panel Layout
4. Screw a No 10 screw into the plugged hole.
Re-position the back box and mark the
remaining two securing holes. Remove the
back box, drill and plug the holes.
5. Re-position the back box and pass all
cables into the base via the appropriate
cable entries, remembering to fit grommets
where necessary.
6. Secure the back box using not less than
30mm x No 10 screws through the three
securing holes.
7. If required install and connect the following:
(a) Digicom or RedCARE STU.
(b) Plug-on digicom type DC54, DC58
DC58M.
(c) Output modules type CPA6.OM.
(d) Printer type DATAC or serial RS232 via a
printer adapter (MPA/DCI).
(e) Relay module type RM.3A.
+ -
V
R25
Mains
Transformer
Mains Cable
Entry
Fused Terminal
Block 315mA
Printed Circuit Board
(PCB)
Battery
Position
Lid and
Back Tamper