TS790+ & TS900+ Installation Manual
Engineer’s Menu 1
27
No/Type
Description
046
Service Call
Activates when the system is on-line
with a remote PC and Lineload
software.
047
System Full Set
Activates when all areas within the
system are set and deactivates when
any area is unset.
048
Custom O/P A
This output is active when a
combination of output conditions
occur. The combinations are
programmed in Engineers Menu 3
(see page 51)
.
049
Custom O/P B
This output is active when a
combination of output conditions
occur. The combinations are
programmed in Engineers Menu 3
(see page 51).
050
PC output 1
This output can be switched on or off
via the PC and “Lineload” software.
051
PC output 2
This output can be switched on or off
via the PC and “Lineload” software.
052
Sounder Control
Normally used as the 0V connection
for an extension loudspeaker so that
only system alarm tones are
generated. Only suitable for Panel
Outputs 1 and 2.
053
Service Required
Activates when the “SERVICE
REQUIRED” message is displayed and
deactivates when the engineer
passcode is entered.
054
Call Engineer
Activates when the system requires
an “Engineer Reset”, deactivates
when the system is reset by the
engineer or “Remote Reset”.
055
Always Off
Never activates.
056
Duress
Activates when a duress passcode is
entered and deactivates when the
duress alarm is reset.
057
System Part Set
Activates when the system is part set,
deactivates when the system is fully
unset or fully set.
058
Battery Fault
Activates when a battery fault occurs
and deactivates when the battery
fault is cleared.
059
Set Fail
Activates when any ward fails to set,
deactivates when the set fail
condition is reset.
060
Open/Close
Activates when the system is unset,
deactivates when the system is
set/part-set.
061
ID Alarm
Activates for 2 seconds when any
circuit causes a new alarm condition.
062
Random
Activates randomly (min = 5 minutes,
max =60 minutes)
063
Modem lockout
Activates when the modem is
locked-out (four failed attempts).
Deactivates when a master user
passcode is entered or after 4 hours.
064
Sndr Control A
Activates when “Ward A” is in entry,
exit, alarm or set fail.
No/Type
Description
065
Sndr Control B
Activates when “Ward B” is in entry,
exit, alarm or set fail.
066
Sndr Control C
Activates when “Ward C” is in entry,
exit, alarm or set fail.
067
Sndr Control S
Activates when “Ward S” is in entry,
exit, alarm or set fail.
068
Chime
Activates for 2 seconds when a
circuit that is programmed as
“chime” is activated.
069
24hr Ccts Omit
Activates when one or more 24 Hour
circuits are omitted.
070
Timed Output
Activates when a “Monitored” circuit
is triggered and remains active for
the duration of the “Monitor Dur"
see
System Timers
.
071
Abort
Activates for 5 seconds after an
alarm is aborted by the user. The
period in which the alarm may be
aborted is set by the “Abort Delay”
see System Timers
.
072
Strobe on Set A
Activates when there is an alarm in
Ward A, and deactivates when the
alarm is cancelled by the user. This
output is also active for 10 seconds
after a user sets Ward A with full alarm
response.
073
Strobe on Set B
See "Strobe on Set A". Applies to Ward
B.
074
Strobe on Set C
See "Strobe on Set A". Applies to Ward
C.
075
Strobe on Set
(System)
Activates when there is an alarm in
on the system, and deactivates
when the alarm is cancelled by a
user. This output is also active for 10
seconds after a user sets any Ward
with full alarm response.
076
Alarm Conf A
This output is active during a
confirmed alarm in Ward A.
077
Alarm Conf B
This output is active during a
confirmed alarm in Ward B.
078
Alarm Conf C
This output is active during a
confirmed alarm in Ward C.
079
Alarm Conf
(System)
This output is active during a
confirmed alarm anywhere in the
system.
080
Active Omit
If an event triggers a latching circuit
type (for example a door or break
glass, but NOT a PIR), and the circuit
remains active until the end of the
confirmation time then the control
panel omits the active zone and
triggers the Active Omit output. The
control panel deactivates the output
when a user disarms the system.
081
Keyswitch
Disabled
The control unit activates this output
when it detects a tamper on the
keyswitch.
100 - 155
Circuit Mimics
Will mimic (active when circuit is
active) circuits 01 to 56 respectively