TS790+ & TS900+ Installation Manual
Oveview
1
Overview
Introduction
The TS790+ and TS900+ alarm control units are
designed for medium to large installations. The
TS900+ can handle from 10 to 56 zones, while
the TS790+ can handle from 10 to 16 zones.
Both systems can be remotely programmed or
interrogated via the telephone line and a P.C.
Both systems can be broken down into 4
separately controlled areas (Wards) so that the
premises or parts of the premises can be
controlled independently.
The TS790+ and TS900+ are based on the
TS790 and TS900, but also offer:
Programmable pins for Plug-on STU or
digicom.
Backtamper and improved lid tamper.
Improved text display for user when setting
the system.
System Architecture
Figure 1. TS790+ and TS900+ Architecture
Control Panel
The control panel is the controlling unit for the
system, it has a power supply and connections
for a standby battery. It has the following
facilities:
8 programmable detection circuits
Bell and strobe outputs
4 programmable outputs (1 x Voltage free
contacts and 3 high current transistorised)
8 programmable digicom/RedCARE
outputs
A connector for a plug-on Menvier
digicom, digi-Modem, or STU
Extension loudspeaker output
All system program information and the
700 event log is stored in a removable non-
volatile memory (NVM)
XNODE
2 Outputs
8 Zones
XNODE
2 Outputs
8 Zones
XNODE
2 Outputs
8 Zones
XNODE
2 Outputs
8 Zones
XNODE
2 Outputs
8 Zones
CONTROL
PA NEL
TS900 NODE
NETWORK
TS900 ID NODE
2 Outputs
8 Zones
30 ID Zones
8 Outputs
(T wo Options)
REMOTE
KEYPAD
Or LEC
1 Outputs
2 Zones
1 Outputs
2 Zones
1 Outputs
2 Zones
1 Outputs
2 Zones
REMOTE
NETWORK
(8 Zones)
Printer
S peaker
CPA6.OM
AUX 12V
Plug-on
Digicom/Modem
Bell output
Strobe output
Digi outputs 1 - 8
Outputs 1 - 4
Plug On
STU
REMOTE
REMOTE
REMOTE
KEYPAD
KEYPAD
KEYPAD
Or LEC
Or LEC
Or LEC
XNODE