Summary of Contents for TS790+

Page 1: ...TS790 TS900 Intruder Alarm Control Panels Installation and Programming Manual...

Page 2: ...re correct errors and omissions escepted However meither the authors nor Cooper Security Limited accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this b...

Page 3: ...Double Pole 14 End Of Line 15 External Sounder Connections 15 Installing an External Sounder from a XNode16 Auxiliary Tamper 17 Extension Loudspeakers 17 Digicom RedCARE Installation 17 Plug on Digic...

Page 4: ...ctive Circuits 3 0 50 Custom Outputs A B 3 A B 51 Custom Output Example 1 51 Custom Output Example 2 51 Custom Output Example 3 51 Modem Options LCD Only 3 C 52 Call Back No 1 52 Call Back No 2 52 Cal...

Page 5: ...the system it has a power supply and connections for a standby battery It has the following facilities 8 programmable detection circuits Bell and strobe outputs 4 programmable outputs 1 x Voltage free...

Page 6: ...ll other system functions are available Remote Arming Station NETARM The Remote Arming Station only allows setting and unsetting of the system The unit has two indicator LEDs the Power LED and a progr...

Page 7: ...0 10 50Hz 5 Control Panel 220mA normal 300mA alarm Battery 12V 7Ah Sealed Lead Acid Power Supply 1 5A LCD keypad 120mA normal 130mA alarm Starburst keypad 120mA normal 130mA alarm LED keypad 120mA nor...

Page 8: ...runs It is recommended that the Menvier 519XB is used in these instances as it can be fault monitored by the control panel Figure 2 TS900 Node Network Wiring Node Network Wiring TS900 Only XNodes requ...

Page 9: ...re 4 TS900 Combined Network Wiring Combined Network Wiring TS900 On some installations it may be desirable to have a remote keypad connected after the XNodes This can be achieved by using an eight cor...

Page 10: ...keyhole position Remove the back box drill and plug the hole Figure 5 TS790 TS900 Control Panel Layout 4 Screw a No 10 screw into the plugged hole Re position the back box and mark the remaining two s...

Page 11: ...TS790 TS900 Installation Manual System Installation 7 Control Panel PCB Layout Figure 6 TS790 TS900 Main PCB...

Page 12: ...JP7 CS to use JP5 without RedCARE JP6 FACTORY RESET If these pins are shorted during power up all system parameters are reset to their factory default settings If the engineer s passcode is lost or f...

Page 13: ...s voltage is below 11V the Battery Fault LED illuminates To clear the fault simply reconnect or replace the battery as appropriate Remote Keypads Four types of remote keypads can be used on the system...

Page 14: ...an only be used to set and unset the system Not fitted on NETLCD Installation Procedure Always ensure that all power mains and battery is removed before making any connections to the remote keypad 1 S...

Page 15: ...lugged on to the control panel JP2 DO NOT plug the Engineer s Keypad into JP1 or you may damage the equipment To convert a standard remote keypad to an Engineers Keypad an Engineer s interface lead is...

Page 16: ...per link to disable tamper switch Tamper switch I D selector 1 5 for TS900 Programmable detection circuits A D Node type From previous XNode or panel Control panel mains power indicator On mains on Fl...

Page 17: ...les or to obstruct the tamper switch TS900 Node Installation TS900 Only The TS900 Node is now obsolete and has been replaced by the TSXNode The TS900 Node allowed you to add an extra eight programmabl...

Page 18: ...base to the wall using the appropriate fixing screws 4 Connect Remote Network cables and detection circuit cables to the appropriate terminals see Figure 13 5 Set the I D selector jumper link to the...

Page 19: ...Used Figure 15 End of Line Wiring External Sounder Connections The following terminals have been provided to allow connections to an external sounder H O This is used to provide a permanent ve hold of...

Page 20: ...e XNode in order to provide sufficient power for the external sounder A relay module such as the Menvier RM3A is also required to drive the external sounder Figure 17 shows the connection details Figu...

Page 21: ...s interface is dedicated to Low Battery You MUST remove the CS link at JP7 before fitting a plug on STU to ensure correct operation of Remote Reset via RedCARE DC POWER This provides the 12V power to...

Page 22: ...utput module connected to the system will indicate circuits 1 to 8 the next modules will indicate circuits 9 to 16 etc Output modules are normally fitted inside the equipment they are controlling and...

Page 23: ...TAC or RS232 printer 3 In order for the printer to work correctly ensure the printer is set to the following Baud rate 4800 Parity None Start bits 1 Stop bits 2 Data bits 8 DTR Normal 4 When set up co...

Page 24: ...ts The control panel has four programmable outputs 1 Set of voltage free changeover contacts rated at 1 Amp 2 Switched ve output rated at 500mA 3 Switched ve output rated at 500mA 4 Switched ve output...

Page 25: ...s manual and that all interconnections are correct A to A B to B etc 2 All system cables are kept clear of mains supply cables telephone cables and R F cables It is recommended that cable ties be used...

Page 26: ...put 4 Detector Reset 003 Panel Output 5 KP1 Code Accepted 009 Panel Output 6 KP1 Code Accepted 009 Panel Output 7 KP2 Code Accepted 009 Panel Outputs Panel Output 8 KP2 Code Accepted 009 Digicom Outpu...

Page 27: ...08 Tamper User Reset Yes 09 Hi Security Engineer No 10 O M s Mimic Ccts Yes 11 Do Battery Test No 12 Final Exit is Night No 13 Audible Time Switch No 14 Show P Set Disp Yes 15 Answer Phone Dft No 16 S...

Page 28: ...ypads will show Engineer on site This message will be cleared the next time a valid user passcode is entered or by exiting the engineer s mode via user menu 1 Menu contents Hotkey Option Page 1 Progra...

Page 29: ...e or when the alarm is cancelled by the user 001 Strobe On Activates when the Strobe trigger is on and deactivates when the alarm is cancelled by the user 002 Switch 12V Activates when the system is s...

Page 30: ...ond time or when the system is reset 026 Comms Failed Activates for 5 seconds when the plug on digicom fails to communicate No Type Description 027 Comms Success Activates for 5 seconds when the plug...

Page 31: ...red or after 4 hours 064 Sndr Control A Activates when Ward A is in entry exit alarm or set fail No Type Description 065 Sndr Control B Activates when Ward B is in entry exit alarm or set fail 066 Snd...

Page 32: ...en triggered it will activate any outputs programmed as Auxiliary 7 Final Exit This must be the first detector or door contact that is triggered when entering the protected area When the setting mode...

Page 33: ...e end of the test period no activations have occurred the circuit is automatically removed from test and behaves as normal The test period is initiated by entering the Engineers passcode The Test attr...

Page 34: ...circuit will re arm before it is locked out of the system This counter has a working range of 000 199 02 Settle Time When setting the system by Final Exit or Exit Terminator detectors that are on the...

Page 35: ...cts this timer option To disable this feature set the timer to 000 This timer has a working range of 000 199 weeks 12 Payment Time The installation company may use this timer to prevent the users from...

Page 36: ...er users have access to the menu This counter has a working range of 000 199 Note Code set Groups are not affected 22 Line Fault Delay This timer delays the audible line fault indication when a teleph...

Page 37: ...ust install a lock switch with the contacts connected to a lockset zone type To set the system the user first enters their access code at a keypad or operates a keyswitch The control unit starts the e...

Page 38: ...nerated This is passed back to the user and on entering the Remote Reset code the system is reset The Remote Reset code is generated using an algorithm identified by a 3 digit number Alternative algor...

Page 39: ...can reset daytime tamper alarms Default Yes 09 High Security Engineer When programmed as Yes the engineer must enter his passcode and remote reset number to gain access to engineer s menu 1 When prog...

Page 40: ...cuit is armed or disarmed Default No 24 Sounder on Confirm When programmed as Yes the control unit activates the internal sounders after a confirmed alarm and any programmed bell delay When programmed...

Page 41: ...rm to Cooper Security Ltd s implementation of the CID standard This option allows you to program the control unit to send tampers as alarm When programmed as Yes then the control unit sends tampers to...

Page 42: ...ardware 1 C The engineer must use this option if they have changed the system hardware configuration while in engineer s mode for example by adding or removing a remote keypad When the engineer tries...

Page 43: ...is selected Each menu option can be selected by pressing the relevant Hotkey Menu Contents Hotkey Option Page 1 View Circuits 40 2 Set System Time 40 3 Set System Date 40 4 Change Passcode 40 5 Chime...

Page 44: ...e 2 2 The system time is displayed in a 24hr format on all remote keypads and is also used to time stamp events in the system event log Set System Time Flowchart Set System Date 2 3 The system date is...

Page 45: ...into four wards areas System A B and C Each ward can then be assigned to passcodes or part set buttons See Part Set Groups on page 47 and Code Set Groups on page 47 Circuits can be assigned to more th...

Page 46: ...stallation Manual 42 Configure Wards Flowchart View System Log 2 9 The engineer can use this option to view the system log The A and C keys allow you to scroll backwards and forwards through the log e...

Page 47: ...T KNOCK 01 56 FIRST 01 56 Fn 01 56 The first activation of a Double Knock circuit FUSE BLOWN 01 FUSE 01 FB 01 Control Panel 12V Auxiliary Fuse blown INACTIVE CCTS 01 56 INACT 01 56 IA 01 56 Inactive c...

Page 48: ...Reset User Code 1 2 0 This option allows the installation engineer to reset the master user user 01 back to the factory default code of 5678 This feature is useful when the master user has forgotten t...

Page 49: ...sing the relevant Hotkey Menu Contents Hotkey Option Page 1 Program Time Switches 46 2 Program Part Set Groups 47 3 Program Code Set Groups 47 4 Edit Engineers Name 48 5 Edit Part Set Text 48 6 Progra...

Page 50: ...programmable time switches Each time switch can be programmed with up to three separate on off times and made to operate on any day of the week The time switches can be assigned to outputs which in t...

Page 51: ...w relevant Part Set Text and after a short delay the system will set the wards that are assigned to the selected Part Set Group Part Set Groups Flowchart Code Set Groups 3 3 This option allows the eng...

Page 52: ...Text LCD Only 3 6 Each detection circuit can have up to 16 characters of text assigned to it Circuit Text Flowchart Custom Text Menu LCD Only 3 7 This menu option allows the installation engineer to...

Page 53: ...456 Part Set Banner The part set banner is a 16 character message displayed on the top line of the display whenever the system is part set If the message is left blank the top line of the display will...

Page 54: ...est Digi Outputs This test routine allows any outputs or digi channels that have been programmed as FIRE P A ALARM and SET to be tested If the system is fitted with a plug on digicom the top line of t...

Page 55: ...le shows how the AND function can be used so that the Custom Output only activates when the system is ward A is set and time switch A is active The table below shows how each switch is programmed to a...

Page 56: ...ogrammed The Modem Password can be up to 16 character long and provides a means of security for remote communications When using the Lineload software the Modem Password in the site profile must match...

Page 57: ...TS790 TS900 Installation Manual Engineer s Menu 3 53 Program Digi Flowchart...

Page 58: ...ered up the control panel logs on the device that is connected to the digicom plug JP3 If the device is changed or removed from the system you must either power the system down and back up again or se...

Page 59: ...302 Low system battery 305 System reset on site or factory 309 Battery test failure 382 Node or Remote removed 401 Open Close by user 406 Alarm cancelled 409 Open Close by keyswitch 411 Call back req...

Page 60: ...Appendices TS790 TS900 Installation Manual 56 Figure 26 A Typical 3 Bedroom House Domestic Part Set Application Example...

Page 61: ...A A O 08 Lounge PIR A A O 09 Bedroom 2 PIR O A O 10 Landing PIR O O O 2 From the above Table create a second Table that details the ward assignment for each circuit The rules for generating the second...

Page 62: ...icks are assigned to the System Ward Circuit Location Ward A Ward B Ward C 01 Front Door 4 02 Smoke Detector 03 Hall door to garage 4 04 Garage door 4 05 Garage back door 4 06 Kitchen door 4 07 Dinnin...

Page 63: ...TS790 TS900 Installation Manual Appendices 59 Figure 27 Commercial Premises...

Page 64: ...4 07 Workshop PIR 3 4 08 Sales Internal Door 4 09 Canteen Door 4 4 4 10 Canteen PIR 4 4 4 11 Stores Entrance 4 12 Stores PIR 4 13 Stores Internal Door 4 14 Sales Office PIR 4 15 Service Entrance 16 Se...

Page 65: ...attribute indicates that the Full Set Group is selected when the circuit changes from Healthy to Active See Program Circuits on page 28 2 Program the code set groups so that all wards are set and uns...

Page 66: ...0A O 4 0AA P 4A 0AAA Q 4AA 0AAAA R 4AAA 0AAAAA S 5CC 0AAAAAA T 5C Setup New Users The TS790 TS900 allows up to 31 users to operate the alarm system each user is assigned a user type and a passcode Us...

Page 67: ...s 02 31 can be programmed as Access When this user type is entered any output that is programmed as Access will activate for a pre set time Normally this user type is used in conjunction with an elect...

Page 68: ...Exit C Part Set C 4 Instant 5 Deferred 6 Lockset 33 7 System Printout 34 8 Remote Reset Algorithm Enter Algorithm number 004 199 34 key Options Page 9 System Configuration No Yes No 00 Bell is an SAB...

Page 69: ...1 B Time Switch B 2 On Time 2 C Time Switch C 3 On Time 3 4 Off Time 1 7 1st operates on 5 Off Time 2 8 2nd operates on 6 Off Time 3 9 3rd operates on 0 Manually Switch Output 46 2 Part Set Groups Ent...

Page 70: ...m 038 Ward C Alarm 039 Ward S Alarm 040 Time Switch A 041 Time Switch B 042 Time Switch C 043 Access Code 044 General Fault 045 Battery Test 046 Service Call 047 System Full Set 048 Custom O P A 049 C...