Log Event Codes
LCD
Starburst
LED
Description
ACTION ALARM
ALM SENT
AA
Bell output activated when system is part-set.
AC OFF
A.C. OFF
PF
Mains power removed.
AC RESTORED
A.C. ON
Pr
Mains power restored
ACCESS 01-31
ACC SS 01-31
Ac.01-31
Access user passcode (01-31) entered.
ALARM 01-56
ALARM 01-56
CA.01-56
Full alarm from circuit (01-56).
ALARM DELAYED 01-56
DELAY 01-56
AD.01-56
Delayed alarm during a part-set condition.
AUX/BELL TAMPER
AUX TAMP
AT
Auxiliary tamper activated.
AUXILIARY 01-56
AUX 01-56
Au.01-56
Auxiliary circuit activated.
BATTERY FAULT
BATT FLT
BF
Battery fault (voltage below 10.5V).
BELL TESTED
BELL TST
BT
External bell and strobes tested.
BELLS REARM
Time and date of bells reinstatement. Separate
from System re-arm.
CALL BACK No. 01-03
C. BACK 01-03
CB.01-03
Modem making a call back to remote PC.
CCTS ISOLATED
24HR OM T
CI
24Hr group omitted during the unset condition.
CCT OMITTED
OMIT D 01-56
CO.01-56
Circuits omitted by the user at time of Setting.
CIRCUITS TESTED 01-56
TEST D 01-56
Tc.01-56
The number of circuits tested during Walk Test.
CODE TAMPER
C.TMP 01-04
PT.01-04
Code tamper from keypad 01-04
COMMS ACTIVE
COM ACT
cA
Plug-on digicom active.
COMMS FAILED
COMS FLT
cF
Plug-on digicom failed to communicate.
COMMS SUCCESSFUL
COMS OK
cc
Plug-on digicom communicated successfully.
DATE CHANGED
DATE CHG
Dc
System Date changed.
DEFAULT CODE
DEFLT 01
DF
User passcode (01) reset to 5678 by the engineer.
DURESS 01-31
DUR SS 01-31
Du.01-31
Duress alarm from user passcode (01-31).
ENTRY 01-56
ENTRY 01-56
En.01-56
Entry timer started by circuit (01-56).
ENTRY ALARM 01-56
EN.ALM 01-56
EA.01-56
Entry timed-out alarm from circuit (01-56).
FACTORY RESTART
FACT. RST
Fr
System “Factory Restarted”.
FIRE ALARM 01-56
FIRE 01-56
FA.01-56
Fire alarm circuit activated.
FIRST KNOCK 01-56
FIRST 01-56
Fn.01-56
The first activation of a Double Knock circuit.
FUSE BLOWN 01
FUSE 01
FB.01
Control Panel 12V Auxiliary Fuse blown.
INACTIVE CCTS 01-56
INACT 01-56
IA.01-56
Inactive circuits during the Unset condition.
KEY SWITCH 01-56
KEY.SW 01-56
So.01-56
Key switch operation from circuit (01-56).
LINE FAULT
LINE FLT
LF
Telephone line fault detected.
LINE RESTORED
LINE OK
Lr
Telephone line fault restored.
LOCKSET LOCKED
Lock switch placed in "locked" position.
LOCKSET UNLOCKED
Lock switch placed in "unlocked" position.
MODEM LOCK-OUT
LOCK-OUT
LO
Modem failed to communicate.
NO EVENT
NO EVENT
--
No log event.
NODE ADDED 01-05
N.ADD 01-05
NA.01-05
Node added to the system.
NODE FUSE 01-05
N.FUSE 01-05
NF.01-05
Node fuse blown.
NODE REMOVED 01-05
N.REM 01-05
Nr.01-05
Node removed from the system.
NODE TAMPER 01-05
N.TMP 01-05
NT.01-05
Node cover removed.
ON-SITE RESTART
SITE. RST
Sr
System “On-Site” restart.
OMITS REMOVED
OMIT REM
Or
Previously omitted circuits reinstated.
PA ALARM 01-56
PA.ALM 01-56
PA.01-56
Panic Alarm circuit activated.
PA CODE 01-31
PANIC 01-56
PC.01-31
Panic Alarm passcode entered.
PANEL LID TAMPER
LID TAMP
LT
Control panel lid removed.
PART SET A/B/C
P.SET A/B/C
PS.A/B/C
System Part-Set using one of the A, B, or C buttons.
PASSCODE 00-31
USER 00-31
Ur.00-31
User passcode entered. (00-31).
PSU OVERLOAD
OL
OL
Power suppy current exceeded.
REINSTATEMENT
Time and date for reinstatement.
REMOTE ADDED 01-04
R. ADD 01-04
RA.01-04
Remote Keypad added to the system.
REMOTE RESET
REM RST
rc
System reset by “Remote Reset” passcode.
REM REMOVED 01-04
R. REM 01-04
rr.01-04
Remote Keypad removed from system.
REM SERVICE CALL
R.S. CALL
SC
Remote service call via “Lineload” software and PC.
REM TAMPER 01-04
R. TMP 01-04
rT.01-04
Remote Keypad cover removed.
SERVICE CALL END
R.S. END
SE
Remote service call finished.
SERVICE REQUIRED
SERVICE
rS
Service required
SET FAIL
SET FAIL
SF
System failed to Set.
SET WARD A/B/C/S
W. SET A/B/C/S
ST.ABCS
Wards A, B, C or System Set.
SYSTEM OPEN
SYS OPEN
OP
System fully unset.