Engineer’s Menu 1
TS790+ & TS900+ Installation Manual
26
No/Type
Description
008
System Set
Activates when any ward is set and
deactivates when the system is fully
unset.
009
Code Accepted
Activates for 5 seconds following
entry of any valid passcode.
010
24 Hour
Activates when a 24Hr alarm is
detected and deactivates when the
alarm is reset.
011
Confirmed
Alarm
Activates when a different detector
causes an alarm and remains active
until a user or engineer resets the
system. This output is normally used
for an ALARM CONFIRMATION signal.
012
Courtesy Light
Activates during entry and when any
remote keypad is used. The duration
of this output is controlled by the
setting of the “COURTESY DUR” timer.
013
Engr On Site
Activates when the engineer’s
passcode is entered and deactivates
when a user passcode is entered.
014
Ccts Omitted
Activates when a user manually omits
any circuit and deactivates when all
circuits are reinstated.
015
Auxiliary
Activates when an Auxiliary alarm is
detected and deactivates when the
alarm is reset.
016
Ward A Armed
Activates when “Ward A” is in exit
mode and when “Ward A” is set.
Deactivates when “Ward A” is unset.
017
Ward B Armed
Activates when “Ward B” is in exit
mode and when “Ward B” is set.
Deactivates when “Ward B” is unset.
018
Ward C Armed
Activates when “Ward C” is in exit
mode and when “Ward C” is set.
Deactivates when “Ward C” is unset.
019
Ward S Armed
Activates when “Ward S” is in exit
mode and when “Ward S” is set.
Deactivates when “Ward S” is unset.
020
Tamper Fault
Activates when a Tamper alarm is
detected and deactivates when the
alarm is reset.
021
Line Fault
Activates when a telephone line fault
is detected and deactivates when
the fault is cleared.
022
Mains Off
Activates when mains power is
removed and deactivates when the
mains power is restored.
023
Exit / Entry
Activates when the panel is in the exit
or entry mode.
024
Test Fail
Activates when a circuit fails test,
deactivates when reset by the
engineer.
025
First Knock
Activates when a double knock
circuit is activated for the first time.
Deactivates when the circuit is
activated for the second time or
when the system is reset.
026
Comms Failed
Activates for 5 seconds when the
plug-on digicom fails to
communicate.
No/Type
Description
027
Comms Success
Activates for 5 seconds when the
plug-on digicom communicates
successfully.
028
Comms Active
Activates when the plug-on digicom
is active and deactivates when the
plug-on digicom is inactive.
029
2nd Entry
Activates when the second entry
timer is started and deactivates when
the second entry timer expires.
030
Entry
Activates when the panel is in the
entry mode.
031
Exit
Activates when the panel is in the exit
mode.
032
Ward A Set Fail
Activates when “Ward A” fails to set
and deactivates when the set fail
condition is reset by the user.
033
Ward B Set Fail
Activates when “Ward B” fails to set
and deactivates when the set fail
condition is reset by the user.
034
Ward C Set Fail
Activates when “Ward B” fails to set
and deactivates when the set fail
condition is reset by the user.
035
Ward S Set Fail
Activates when “Ward S” fails to set
and deactivates when the set fail
condition is reset by the user.
036
Ward A Alarm
Activates when a circuit in set “Ward
A” causes an alarm and deactivates
when the alarm in “Ward A” is reset.
037
Ward B Alarm
Activates when a circuit in set “Ward
B” causes an alarm and deactivates
when the alarm in “Ward B” is reset.
038
Ward C Alarm
Activates when a in set “Ward C”
causes an alarm and deactivates
when the alarm in “Ward C” is reset.
039
Ward S Alarm
Activates when a circuit in set “Ward
S” causes an alarm and deactivates
when the alarm in “Ward S” is reset.
040
Time Switch A
This output is controlled by the settings
of “Time Switch A” (see Engineers Menu
3)
041
Time Switch B
This output is controlled by the settings
of “Time Switch B” (see Engineers Menu
3)
042
Time Switch C
This output is controlled by the settings
of “Time Switch C” (see Engineers Menu
3)
043
Access Code
Activates when an “Access”
passcode is entered. The duration of
this output is controlled by the setting
of the “Acc.CODE DUR” timer (see
System Timers).
044
General Fault
Activates during battery fault or when
the system is prevented from being
set. Deactivates when all faults are
cleared.
045
Battery Test
Activates for 1 minute on the hour
every hour. This output is used to test
the battery in remote PSU using a
519FM monitor PCB).