65
RECORDING (CONTINUED)
AUTOMATIC RESTORE TECHNOLOGY SYSTEM (A.R.T.S.):
When AC power fails accidentally, this recorder will resume to last operating status as soon as power supply resumes. For
example, if the unit is in the Timer mode (waiting for the preset program time), it will restores to Timer mode after the power
is lost and then reapply. The Timer programs and the Real Time Clock will be kept for at least two days during the power
loss/failure. But if power failure happens longer than two days, the user should check or may need to correct both the Real
Time Clock and the Timer programs. In case the power failure happens while Timer recording is taking place, this recorder
will first try its best to recover the recorded title before continuing the remaining recording (if program time has not expired)
or Timer mode (waiting for next preset program).
Timer Recording:
When the power failure occurs during the timer recording,
the unit will recover automatically and a “ Recovering Title ”
message box will be displayed on the screen.
1
After the unit has collected all the required information and
data, it will start the recovery process.
2
Once the recovery process has successfully completed, a
successful recovery message box will be displayed on the
screen. If the power is resumed while the timer program is
still in valid stage, the unit will resume to the timer recording
program mode and continue recording until the program
ends.
3
Normal Recording:
When the power failure occurs during the normal recording,
the unit will recover automatically and the recovery process
will be the same as the Timer Recording. However, the only
difference is the unit will resume to the normal Stop mode
after recovering successfully from the power failure.
4