Forks with master-slave function
– flow meter without Autostop
The flow meter needs to be
connected to the return flow of the
left fork. Remove the plugs from the
flow meter. Connect one port of the
flow meter to the ‘R’ port on the left
fork.
Connect the other port of the flow
meter to the return hose of the lift
truck.
Check all connections for leakage
before operation. Fully extend and
retract the forks five times to remove
any air from the hydraulic system.
17
T
P
Lift truck
Flow meter
Left fork
Right fork
O
C
C
R