Appendix D — Specifications
Electrical Specifications
Specfication—Surge Test
Baker PPX30
Baker PPX40
Baker PPX30A
Maximum output voltage
30,000V
40,000V
30,000V
Maximum output current with
leads shorted together
1400A
2600A
1400A
Maximum impulse energy
45J
120J
45J
Accuracy
12%
12%
12%
Specfication—DC HiPot Test
Baker PPX30
Baker PPX40
Baker PPX30A
Maximum output voltage
30,000V
40,000V
30,000V
Voltage accuracy
3%
3%
3%
Maximum output current
1000µA
1000µA
1000µA
Current accuracy
5%
5%
5%
Overcurrent trip
12/120/1200µA
12/120/1200µA
12/120/1200µA
Current resolution
1/10/100µA
1/10/100µA
1/10/100µA
Specfication—Armature bar-to-bar test
Baker PPX30A only
Maximum voltage
(no load) 2100V
Maximum current
7000A
Maximum pulse energy
45L
Maximum test inductance
20 µH
Minimum test inductance
0.4 µH
General Specifications
Specfication
Baker PPX30
Baker PPX40
Baker PPX30A
Weight
310 lbs (141 kg)
290 lbs (132 kg)
321 lbs (146 kg)
Dimensions
24 x 48 x 33 in
(610 x 1219 x 838 mm)
24 x 48 x 33 in
(610 x 1219 x 838 mm)
24 x 48 x 33 in
(610 x 1219 x 838 mm)
Power
requirements
100 - 120V, 5A, 60 Hz, 500W
200 - 240V, 3A, 50 Hz, 600W
100 - 120V, 5A, 60 Hz, 500W
200 - 240V, 3A, 50 Hz, 600W
100 - 120V, 5A, 60 Hz, 500W
200 - 240V, 3A, 50 Hz, 600W
Test leads
3
1
3 + 1 (armature)
Operates with
Baker AWA, DX
Baker DX
Baker AWA, DX
Environmental Specifications
Specfication
Detail
Operating temperature range
and humidity
Only operate the tester in temperatures ranging from 5 to 40° C (41 to 104° F).
This unit is for use at a maximum relative humidity of 80% for temperatures up
to 31 °C (88 °F), decreasing linearly to 50% relative humidity at 40° C (104° F).
Maximum altitude
The unit has been tested for use up to 2,000 m (6,500 ft.).
Pollution degree II
This unit is intended for Installation Category II in a Pollution Degree II
environment.
(From IEC 61010-1 3.6.6.2) Only non-conductive pollution occurs. However,
temporary conductivity caused by condensation is expected.
www.megger.com 73
Summary of Contents for PPX30
Page 1: ...Baker Power Packs PPX30 PPX30A PPX40 User Guide...
Page 2: ......
Page 6: ...Notices iv Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Page 12: ...Baker Power Pack Introduction 4 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Page 24: ...Baker Power Pack Setup 16 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Page 74: ...66 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Page 78: ...70 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Page 82: ...74 Baker Power Packs User Guide 71 061RC EN V2 www megger com...