PRINTER TESTS WITH HSP-2208-GB
7.1
LONG RUN TEST
The following tests were performed with KPW-460 1st Gen without any
preprints. The results with preprints are worse in terms of the
possible humidity.
•
voltage: 12 VDC
•
18 - 24°C 45-50%RH
•
density 25
•
time between printouts 8 seconds
Figure 15
Printer 1: Controller GCT-4695 paper KPD-460
436,285 tickets printer OK
Printer 2: Controller GCT-4695 paper T7034
431,072 tickets printer OK
Printer 2: Controller GCT-4695 paper KPW-460
441,949 tickets printer OK
7.2
ENVIRONMENTAL TEST
Time between printouts 10 seconds at -20°C
13,716 tickets
Time between printouts 30 seconds at +60°C/90% RH
8,926 tickets
7.3
MONDAY MORNING TEST
60°C/90%RF, one day (8 h) one printout per minute – next day one printout
7.4
CYCLE TEST
(KPW-460 1.Gen and KPW-460 2.Gen - blanco without blackmark)
In order to simulate real printer operation under fluctuating environmental conditions, a cycle test according to ICE60068-
2-30 was carried out at GeBE. Each cycle test was performed with max. 90%RH (specified) and 95%RH and passed.
Figure 16
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. GPT-467x-C32-E-MAN-V1.0-1001
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
May 19, 2021
Beethovenstrasse 15
page 28 | 112
82110 Germering
Our general terms of business are to be applied.
Germany
www.gebe.net
Errors and changes reserved.
28