CURRENT SETTING DEPENDING ON THE FUSE @24 VDC
These maximum peak currents are only allowed for a short time, otherwise the fuse can be damaged.
This setting is recommended if e.g. the printout contains single horizontal dot lines.
5.2.1 SETTING GPT-4672 for HSP-2208 @24V / HSP-2108 @12 V
F1 = 4.0 A
default
→
parameter value 18,8:
19
F1 = 4.0 A
max.
→
parameter value 18,8:
28
Optional fuse on request:
F1 = 2.5 A
default
→
parameter value 18,8:
8
F1 = 2.5 A
max.
→
parameter value 18,8:
12
F1 = 5.0 A
default
→
parameter value 18,8:
28
F1 = 5.0 A
max.
→
parameter value 18,8:
56
5.2.2 SETTING GPT-4673 for HSP-3208 @24 V
F1 = 4.0 A
default
→
parameter value 18,8:
20
F1 = 4.0 A
max.
→
parameter value 18,8:
27
Optional fuse on request:
F1 = 2.5 A
default
→
parameter value 18,8:
8
F1 = 2.5 A
max.
→
parameter value 18,8:
12
F1 = 5.0 A
default
→
parameter value 18,8:
27
F1 = 5.0 A
max.
→
parameter value 18,8:
56
At 12 V (10.8 – 13.8 VDC) operating voltage for HSP-2208 or HSP-3208 the currents are halved. Thus, the double parameter values
can be set.
Attention: the print speed must be set to 70 mm/s at 12 V operation (parameter 18,3 = 70).
5.2.3 SETTING GPT-4673-M 300dpi for HSP-3512 @24 V
F1 = 4.0A
default
→
parameter value 18,8:
24
F1 = 4.0A
max.
→
parameter value 18,8:
40
Optional fuse on request:
F1 = 5.0A
default
→
parameter value 18,8:
40
F1 = 5.0A
max.
→
parameter value 18,8:
60
ATTENTION:
All measurements for device safety and EMC were carried out with the standard setting for parameter 18,8.
Changing this value may require new measurements in the customer application.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. GPT-467x-C32-E-MAN-V1.0-1001
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
May 19, 2021
Beethovenstrasse 15
page 26 | 112
82110 Germering
Our general terms of business are to be applied.
Germany
www.gebe.net
Errors and changes reserved.
26