Page 13
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 4 - General Informaton
Emergency Systems And Procedures
IF THE CONTROL SYSTEM FAILS WHILE THE PLATFORM IS ELEVATED,
HAVE AN EXPERIENCED OPERATOR USE THE EMERGENCY LOWERING
PROCEDURE TO SAFELY LOWER THE PLATFORM������
DO NOT ATTEMPT TO CLIMB DOWN ELEVATING ASSEMBLY������
Emergency Stop
The machine is equipped with an EMERGENCY STOP switch on both control panels.
Press the EMERGENCY STOP switch at any time to stop all machine functions.
Turn switch
clockwse
to reset.
Selector Switch Set To Platform
Either switch will stop all machine functions.
Both switches must be reset or machine will not operate.
Selector Switch Is Set To Base
The upper controls are locked out.
The lower controls switch must be reset or the machine will not operate.
The machine will operate from the lower controls if the upper controls switch is tripped.
Emergency Lowering
The Emergency Lowering System is used to lower the platform in case of power failure.
The Emergency Lowering switch *will* continue to function if the EMERGENCY STOP switch is
tripped.
To lower the platform, perform the following steps:
Push and hold the toggle switch down to lower the platform.
Once the platform is fully lowered, release the toggle switch.
ART_3107
91843
Emergency Stop Switch
Upper Controls
Lower Controls
Emergency Lowering Switch
•
•
1.
2.
•
•
•
•
•
•