Page 130
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 9 - Troubleshootng - 3084ES Models
SYSTEM
2A
MODE
PRESS ENTER
FOR MESSAGES
2A-1
SUPPLY
2A-2
ON/OFF
2A-3
MOTOR VOLTS
ACTUAL
2A-4
MOTOR AMPS
ACTUAL
2A-5
TEMPERATURE
OF P600
CONTROLLER
2A-6
TILT
2A-7
DIAGNOSTIC
Use in conjunction with
Diagnostic tables for
Thorough explanation
Of personalities and values
XX84RT SERIES ANSI & CE
EZ-CAL MENU
2
DIAGNOSTICS
ENTER
TILT FILTERED
NOT USED
2A-7A
TILT LOCAL
GP400 LEVEL
2A-7B
TILTED
YES OR NO
2A-8
ENTER
ENTER
ENTER
SUPPLY
BATTERY VOLTS
2A-2A
SUPPLY
CAP BANK
2A-2C
AXLE
ENTER FOR INFO
2A-15
HEIGHT
ACTUAL IN %
2A-9
LOAD
OVERLOAD
PROTECTION ONLY
2A-10
OVERLOADED
YES or NO
2A-11
LAST MOVED
NOT USED
2A-12
ELEVATED
YES or NO
2A-13
OUTRIGGERS
AUTO-LEVEL INFO
2A-14
SYMBOL
KEY FUNCTIONS
EZ-Cal Flow Chart
ESC/ENTER BUTTONS
To move back and forth between
Menu and sub-menu
LEFT/RIGHT BUTTONS
Select menus and setting to be adjusted
UP/DOWN BUTTONS
Adjust setting values
PLATFORM
2B
ENTER
TRIGGER
ON/OFF
2B-1
DLD
ACTUAL
2B-2
JOYSTICK
ACTUAL DEG OF
MOVEMENT
2B-3
FWD / UP
FWD JOYSTCK
MOVEMENT
2B-4
REV / UP
REV JOYSTICK
MOVEMENT
2B-5
LEFT(STEER)
ON/OFF
2B-6
RIGHT (STEER)
ON/OFF
2B-7
GROUND
2C
UP
ON/OFF
2C-1
DOWN
ON/OFF
2C-2
ENTER
INPUTS
2D
ENTER
P7-1
12 V SUPPLY
2D-1
P7-2
BASE SELECTED
2D-2
ANALOGS
2E
ENTER
OUTPUTS
2F
GP400 ANALOGS
MAIN CPU
2E-1
CALDATE
DATE OF
CALIBRATION
2G-1
SOFTWARE
SOFTWARE
VERSION NUMBER
2G-2
MAX BATTERY
HIGHEST BATT
VOLTAGE
2G-4
BOOM GP400
ALL CIRCUITS 12V
ONLY
ENTER
VALVE SUPPLY
OUT
NOT USED
2C-3
IN
NOT USED
2C-4
P7-3
UP
SELECTED
2D-3
P7-4
PLATFORM
SELECTED
2D-4
2D-5
2D-6
P7-12
ENG START
2D-7
GEN STATE
HYBRED OPTION
2A-16
M2-6
POTENTIOMETER
2E-2A
ENTER
MATRIX
ANALOGS
UPPER CONTROL
2E-2
P4-1
CHOKE, PREHEAT
2F-1
P4-2
STARTER
2F-2
P4-4
THROTTLE
2F-3
P4-7
ALTERNATOR
EXCITE
2F-4
P4-8
IGNITION,
FUEL
2F-5
P4-14
DOWN VALVE
2F-6
P5-1
LIFT VALVE
2F-7
P5-2
STEER RIGHT
2F-8
P5-3
STEER LEFT
2F-9
P5-6
ALARM
2F-10
P5-9
HOUR METER
2F-11
P5-14
STRT INHIBIT
LIGHT
2F-12
P6-1
LEVEL BACK
2F-13
P6-2
LEVEL FORWARD
2F-14
P6-3
LEVEL RIGHT
2F-15
P6-4
LEVEL LEFT
2F-16
LOG
2G
ENTER
POWERED
ACCUMULATED
HRS ON GP400
2G-3
ENTER
P8-2
ANGLE
TRANSDUCER 1
2E-1A
AIRTRAX
NOT USED
2B-10
2D-8
P8-5
ANGLE
TRANSDUCER 2
2E-1B
P8-6
PRESSURE
TRANSDUCER
2E-1C
P8-9
TBM IN
2E-1D
P6-13
AXLE LOCK
2F-17
P6-15
A/C GENERATOR
2F-18
NOTE:
All other plug numbers shown on the EZ-cal
but not listed here are not used on this model
SUPPLY
12 VOLT SUPPLY
2A-2B
SUPPLY
BATT SCALE
2A-2D
ENTER
HEIGHT 1
ANSI & CE
2A-9A
HEIGHT 2
CE ONLY
2A-9B
ENTER
AXLE
ANSI & CE
2A-15A
AXLE LOCKED
YES OR NO
2A-15B
AXLE ANGLE
IN DEGREES
2A-15C
GEN RMS
PRESS ENTER
2A-16C
TRMS
2A-16C1
GEN DEB
2A-16A
GEN RPM
2A-16B
ENTER
ENTER
POSITRACK
ON/OFF
2B-8
AUTO-
POSITRACK
ON/OFF
2B-9
ENTER
P7-7
DOWN SELECTED
P7-10
ENG PRE-HEAT
P7-13
ENG OIL PRESSURE