General
E-1
Appendix E
Configuration Parameters
E.1 General
This appendix lists the various parameters that can be used to configure the
MX-2100.
System Configuration Parameters
The following table
lists the available system configuration parameters that can be
configured from the front panel, and their functions. The table also lists the
parameter values included in the MX-2100 default configuration. Refer to the
Operation
chapter for information on additional system parameters.
Table E-1. System Parameters
Designation Function
Values
CLK_MASTER
Selects the master timing
reference for the main link
transmit path.
This parameter is displayed only
when the main link interface is
DCE or external DCE (E-DCE),
which are available only with the
KML.1, KML.2, KML.3 KML.4 and
KML.F modules using the TE
mode. It is not displayed when a
KML.5, KML.6, KML.7, KML.8,
KML.10 module is installed.
INT
- Internal oscillator
i:j
- Locked to the external clock received
from the indicated data channel. This
selection is available only when the MX-2100
enclosure includes I/O modules with
synchronous data channels which support the
DTE2 timing mode, e.g., KLS.1, KHS.1,
modules with ISDN interface, e.g., KHS.U or
KVF.4/S0, or modules with T1 or E1 interface,
e.g., KVF.5. Only channels of such modules
are available for selection on the LCD. Note
that the selected channel must actually use a
timing mode which supports the connection
of an external timing reference, e.g., the
DTE2 mode for synchronous data channels,
the TE or LT mode for ISDN channels, or
loopback timing for T1 or E1 interfaces). A is
the MX-2100 I/O slot number (1 through 12).
B is the module channel number, 1 or 2.
Default: INT