Alarm Messages
B-1
Appendix B
Alarms
B.1 Alarm Messages
Table B-1
lists the alarm messages displayed by the MX-2100. For each alarm, two
versions are given: a concise version (maximum 16 characters) displayed on the
LCD, and the version sent to the terminal. In addition to the text, each message
has a code number.
Table B-1
lists the messages in ascending order of their code
numbers, and in addition, indicates their type (state or event) and lists the actions
required to correct the alarm condition. Perform the corrective actions in the given
order, until the problem is corrected.
In the following table, i indicates the slot number contained in the alarm message.
Table B-1. LCD Alarm Messages
Code Message - LCD
Message - Terminal
Alarm
Type
Description
1 HDR
FAILURE HARDWARE
FAILURE,
SLOT i
State
A technical failure has been detected in
the module installed in the specified slot
(ML-A, ML-B, 1 through 12). Replace
the module
2
LOC SY LOSS
LOCAL SYNC LOSS
State
The KML module installed in the
specified slot (ML-A, ML-B) lost
synchronization to the incoming data
stream. May indicate a configuration
error or a technical failure
3
B.R.G FAIL
B.R.G FAILURE,
SLOT i
The baud rate generator of the module
installed in the specified I/O slot
(1 through 12) failed. Replace the
module
4
PS-A 5V FAIL
PS-A 5V FAILURE
State
The 5V voltage provided by the KPS-A
module is missing or is out of the
allowable limits. Replace the module
5
PS-A 12V FAIL
PS-A 12V FAILURE
State
One or both of the
±
12V voltages
provided by the KPS-A module is
missing or is out of the allowable limits.
Replace the module
6
PS-B 5V FAIL
PS-B 5V FAILURE
State
The 5V voltage provided by the KPS-B
module is missing or is out of the
allowable limits. Replace the module
Note