Appendix B Alarms
Alarm Messages
B-3
Table B-1. LCD Alarm Messages (Cont.)
Code Message - LCD
Message - Terminal
Alarm
Type
Description
18 ML
FLIP
OCCURRED
MAIN LINK FLIP
OCCURRED
Event
The MX-2100 switched to operation on
the second main link. This message can
be displayed only when the redundancy
mode is used
19
ML SIG LOSS
ML LOSS OF SIGNAL,
SLOT i
State
The KML.5 module installed in the
specified slot (ML-A, ML-B) does not
receive data (only for KML.5 module)
20 MDL
REMOVE MODULE
WAS
REMOVED, SLOT i
Event
The module that was previously installed
in the specified slot (ML-A, ML-B and 1
through 12) has been physically
removed, or has been reset, or the
communication with the module failed
21
BACKUP DIAL FAIL
MAIN LINK BACKUP
DIAL FAILURE
Event
The connection of the switched backup
link failed. This message can be
displayed only when the switched
backup mode is selected
22
BACKUP ML ACTIVE SWITCHED BACKUP
ML IS ACTIVE
Event
The switched backup link has been
successfully connected and is actively
carrying traffic. This message can be
displayed only when the switched
backup mode is selected
23
ML RECOVERY
MAIN LINK RECOVERY Event
The main link has returned to normal
operation. This message can be
displayed only when the switched
backup or priority bumping mode is
selected
24
PB FP TO ML-A
ACTIVE
MAIN LINK FLIP, ML-A Event
Main link A is now the active link, after
a flip from link B. This message can be
displayed only when the priority
bumping mode is selected
25
PB FP TO ML-B
ACTIVE
MAIN LINK FLIP, ML-B Event
Main link B is now the active link, after
a flip from link A. This message can be
displayed only when the priority
bumping mode is selected
26
DB SWITCH TO DB1 DATABASE SWITCH TO
DATABASE 1
State
The local MX-2100 unit automatically
switched to data base 1, in accordance
with the time specified by means of the
DEF DB FLIP
27
DB SWITCH TO DB2 DATABASE SWITCH TO
DATABASE 2
State
The local MX-2100 unit automatically
switched to data base 2, in accordance
with the time specified by means of the
DEF DB FLIP