Chapter 4 Operation
MX-2100/2104
Installation and Operation Manual
4-18
Operating Instructions
•
Check the settings of switch SW3 on the KCL module:
Section 1 - Master/Slave: OFF
Section 2 – DB INIT: OFF
Section 3 – PSWRD: OFF
Section 4 – DEBUG: OFF
•
Check that all the communication equipment serving the main links operates
properly.
•
Check all the configuration parameters against the prescribed set of
parameters.
•
Press the RESET push-button of the KCL module.
If these actions do not correct the problem, refer to
Chapter 5, Diagnostics
to
identify the fault and replace the corresponding module.
Turn Off
➤
To stop equipment operation, use the following procedure:
1. If the MX-2100 includes a KM-Ringer module, first turn the KM-Ringer off
before the MX-2100.
2. Turn the MX-2100 off by setting the ON/OFF switches of the KPS modules
installed in the enclosure to OFF.