Chapter 4 Operation
MX-2100/2104
Installation and Operation Manual
4-2
MX-2100 Supervision Language
•
Commands are case-insensitive, e.g., you can type commands in either lower
case and/or upper case letters.
•
To correct typing errors, press the BACKSPACE key until the error is cleared,
and then retype the correct command.
•
Use a space as a separator between command fields and/or parameters.
•
Commands must end by pressing ENTER.
•
To use a command with the existing parameters, type the command name and
press ENTER.
•
To cancel the current command, press the BREAK key, or CTRL-C (that is, hold
the CTRL key down and type C). You will obtain the MX-2100 prompt again.
•
To repeat the previous command, press CTRL-A.
•
To repeat the previous command followed by pressing ENTER, press CTRL-D.
Command Options
The following general types of options shown in
Table 4-1
are available with some
commands. For details refer to the
relevant appendix.
Table 4-1. General Command Options
Option Meaning
Example
of
Usage
/A
All
CLR ALM /A
Clears all the alarms stored by the alarm buffer
/C Clear
DSP
ALM
/C
Display all the alarms stored by the alarm buffer and
then clear all the event alarms
/CA
Clear all
DSP ALM /CA
Display all the alarms stored by the alarm buffer and
then clear all the alarms
*
Display all the relevant
information for the
requested item
DSP REV *
Displays the hardware and software revisions of all the
modules installed in MX-2100