background image

Safety and Warning Information 

Important Notice

  -  Before utilizing the product, the user should 

determine the suitability of the product for its intended use.  The 

user assumes all risk and liability in connection with such use.  

ULTRA ELECTRONICS’  WRITTEN WARRANTY FOR THE 

PRODUCT IS MADE IN LIEU OF ALL OTHER WARRANTIES, 

EXPRESSED OR IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE.  The user's exclusive remedy for breach of  Ultra 

Electronics' written warranty shall be the repair or replacement of 

such quantity of product which is proven to be defective.  In no 

case shall Ultra Electronics be liable for any special, incidental, or 

consequential damages based upon breach of contract, 

negligence, strict liability or other legal theory. 

Approval Agency Controlled Document 

No changes authorized without prior agency approval 

Publication Number: 

 

    RM0900202  Rev. 0 

Installation Instructions 

Original Instructions 

 

 

MX Multiplexer Base Modules 

 

For use ONLY with the  

EOTec MX Multiplexer Line 

 

Ultra Electronics 

N

UCLEAR SENSORS & PROCESS INSTRUMENATION 

707 Jeffery Way, PO Box 300 

Round Rock, TX 78680-300 USA 
Toll Free:   800-880-9333            

Telephone:  +1 512-434-2850 

Fax:  +1 512-434-2901 
Email:  [email protected] 

www.ultra-nspi.com 
Ultra Electronics, Nuclear sensors & Process 

Instrumentation is a business name of Weed Instrument 

Co., Inc

 

 

When operating, do not look directly 

into the transmit optical port or use 

magnification or focusing equipment to 

view optical output. 

IEC 60825-1, Class 1 Laser Product 

FDA 21 CFR 1040.10 & 1040.11 

CAUTION: Use of controls and/or adjustments or the 

performance of procedures other than those 

specified herein may result in hazardous radiation 

exposure. 

 

Connect the DIN Rail, via the Model 

2A09 End Clamp, to Protective Earth 

(PE) ground with low impedance.

 

ATEX Specific Conditions of Use 

Modules shall be installed in an enclosure which 

maintains an ingress protection rating of IP54 and meets 

the enclosure requirements of EN60079-0 and 

EN60079-15.  The EOTec modules shall be installed in 

DIN rail with DIN end clamps mounted on both sides of 

the module set.  The DIN rail must be connected to 

Protective Earth in order to provide modules with  a 

Protective Earth connection.  Do not disconnect 

equipment connections or modules when energized. 

 

 

 

 

Nuclear Sensors & 

Process Instrumentation 

 

Power:

  At the top of the module, a pluggable screw 

terminal block is provided to apply power from a, 

nominal 24Vdc source.  The MX Base Module 

provides  this  received  power to all additional I/O 

modules connected via the 10+2  integrated BUS 

interconnection.  

Alarm Relay:

  Also, at the  screw terminal block  are 

contacts of a Form-C (SPST) Alarm Relay which 

provide a remote fault indicator. There are four faults 

that will engage the relay: An I/O module mismatch, a 

loss of power, a loss of the optical signal, or a loss of 

the optical signal at remote receiver will set this alarm 

(engage relay). 

SFP:

  MX Base modules use Small Form-factor 

Pluggable (SFP) transceivers with LC connectors.  

This replaceable transceiver determines the transmit 

and receive specifications of the MX Base module. 

 

Connections 

EOTec MX Multiplexer Models 

MXB-MM2 / MXB-SM15 

MXB-SM40 / MXB-SM80 

MX Base Modules 

 

Service 

 

Service of this equipment is to be performed by Ultra 

Electronics, NSPI only.  This unit has no scheduled 

replacement  of parts.  For installation manuals in a 

community language other than English please contact 

Ultra Electronics, NSPI. 

 

Reviews: