7 - CONTROL PANEL
The default temperature is 65°C and it can not be set below 50°C or above 80°C.
To adjust it: press any button; press the "menu" button, via the scrolling buttons display the “SET TEMP.H2O” screen; press the “SET” button;
set the desired temperature via the “<>” scrolling buttons; confirm the temperature with the “OK” button.
MANDATORY EXTERNAL ROOM THERMOSTAT (3) OR STORAGE TANK CONNECTION
It is necessary to connect the stove to external thermostat “3” or a storage tank; it is also possible to set up a connection with home
automation control unit “4”. If you wish to connect the modem, you must do so with terminal “2”.
For the connection it is necessary to connect the cables to the product board in the positions identified below.
The terminal in the photo
provides a 230V
power supply for any thermostats. Check the required supply voltage in the instructions for
the thermostat being installed.
It is not necessary to activate the room thermostat or storage tank from the control panel when the default is active.
We recommend having installation carried out by an authorised technician, in compliance with regulations in force in the
country of use.
1
COMPUTER CONNECTION (to be carried out by a specialised technician)
2
MODEM CONNECTION
3
EXTERNAL ROOM THERMOSTAT CONTROL UNIT CONNECTION
4
HOME AUTOMATION CONTROL UNIT CONNECTION
5
WIRELESS PROGRAMMABLE THERMOSTAT (OPTIONAL)