Maintenance and cleaning
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
gaskets on the fire door. If necessary, contact an authorized service
centre to have them replaced
MCZ suggests relying on an authorized service centre
for end-of-season cleaning and maintenance, who
will carry out all of the previously mentioned work
and make a general check of the stove's components.
5.2.6.
Shutting the stove down (end of season)
At the end of season, we recommend completely removing pellets from
the hopper with the use of a vacuum cleaner with an extension.
In the period when the unit is out of use it must be
disconnected from the electricity mains.
Upon re-start, when
pressing the main switch does not cause the control panel display to
light up, it could mean that the service fuse needs replacing.
On the main button there is a fuse box which is located above the
power socket. Use a screwdriver to open the fuse-holder compartment
and if necessary replace them (3.15 A delayed)
5.2.7.
Check of internal components
ATTENTION!
The check of the internal electro-mechanical
components must be carried out only by qualified
personnel with technical knowledge of electricity and
combustion.
We recommend that an annual maintenance service is carried out,
preferably under a programmed service contract. The essential part of
this service is a visual and functional check on the internal components:
The following is a summary of the checks and/or maintenance tasks
which are indispensable for the correct operation of the stove.
PARTS / INTERVAL
1 DAY
2-3 DAYS
30 DAYS
60-90 DAYS
1 YEAR
Grate
●
Ash collection
t
t
●
Ash drawer
●
Glass
●
Lower heat exchanger
●
Complete exchanger
●
Smoke duct
●
Door seal
●
Air filter
●
Flue pipe
●
Remote control battery
●