Chapter 3
INSTALLATION AND USE MANUAL
page
18
Installation and fitting
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
It is mandatory to provide for correct insulation of the
tube if it is mounted on the left side near the smoke
exhaust.
MCZ declines any responsibility in case of non-
observance of the aforementioned warnings. Fire risk!
3.5.1.
Side installation of chute
In case the chute is positioned on the side, the distance from the axis
of the machine to the wall must be at the most 80 cm (see figure).
To position the chute, proceed as follows:
•
Connect the provided tube to the Powerbox, being careful that
the tube is turned to the side, and attach it with the strap.
•
Connect the tube (in the upper part) to the hole in the door
using the provided strap.
•
Position the tube with the door frame in a way that it will be
possible to screw it in and mount it to the cladding near the
hole once the cladding is in place.
•
To assemble the exterior door, refer to paragraph 3.15, since
this operation must be executed once the cladding is in place.
3.5.2.
Front installation of chute
•
Connect the provided tube, being careful that the tube is
turned forward, and attach it with the strap.
•
Connect the tube to the hole in the door using the strap.
•
Position the tube in a way that renders it accessible once the
cladding is in place and that allows mounting the door structure
to the cladding.
•
To assemble the exterior door, refer to paragraph 3.15, since
this operation must be executed once the cladding is in place.
3.6.
COMBUSTION AIR AND AIR FILTER
The PowerSystem is equipped with a combustion air intake that
allows the intake of air that is essential to combustion. This
intake is located on the rear of the unit. It is equipped with a
pollen filter that can be easily cleaned. It is advisable to draw
combustion air from inside the room of installation and
not from
outdoors.
This will prevent intake of impurities, dust or
humidity.
The air filter is cylindrical. It is located just back of the unit at
the start of the tube. It is composed of a fine metallic mesh.
The filter must be regularly services. To reach it, the combustion
chamber must be extracted on its slides. To do this, refer to the
chapter on maintenance.
Installation of standard nozzles for hood
ventilation
Installation of side chute
Installation of the front chute