Chapter 4
INSTALLATION AND USE MANUAL
page
45
Operation
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
to shut down due to lack of fuel. This is indicated by the steady
message
PELLET
. This is cancelled as with the other alarms, i.e. by
turning the switch OFF for a few seconds (after filling the hopper with
pellets).
4.17.
SYNCHRONIZATION OF REMOTE CONTROL
Upon first start-up of the product, it may be necessary to get the stove
to recognize the new remote control. To carry-out this operation, follow
the simple instructions that follow:
•
connect the stove to the socket and switch the power supply
button on
•
ensure that the selector
D
of the emergency panel is in the
position
REMOTE
•
when the first text appears onto the display of the emergency
panel, press the embedded button
G
with the aid of a pointy
object (toothpick..)
•
three flashing lines “---“ will appear on the display. Press the
on/off button of the remote control for confirmation.
The three flashing lines will disappear from the display and the stove
will recognise the new communication address of the remote control.
Recognition will also be confirmed by 4 acoustic sounds.
4.18.
SAFETY DEVICES
The stove is fitted with the following safety devices:
•
PRESSURE SWITCH
Monitors depression in the smoke duct. It is designed to shut
down the pellet feed screw in the event of an obstructed flue or
significant back-pressure (from the wind).
•
SMOKE TEMPERATURE SENSOR.
Monitors the temperature of the smoke, and gives permission for
start-up or shuts the stove down when the smoke temperature
falls below the preset value.
•
PELLET HOPPER TEMPERATURE SENSOR.
If the temperature exceeds the preset safety level, it immediately
shuts down the running of the stove, and has to be reset
manually, after the stove has cooled, before the it will restart.
•
ELECTRICAL SAFETY
The stove is protected against violent surges of current by the
main fuse, which is located on the control panel at the rear of the
stove. Other fuses to protect the electronic boards are to be found
on the boards themselves.
•
FAILURE OF THE SMOKE EXTRACTION FAN
If the fan stops, the electronic board shuts off the supply of pellets
in good time, and an alarm is displayed.
•
BREAKDOWN OF THE REDUCTION MOTOR
- OFF
- REMOTE
- ON
- MIN
- MED
- MAX
D
G