Chapter 4
INSTALLATION AND USE MANUAL
page
34
Operation
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
mode, by pressing button
5,
only the desired room temperature is
adjusted.
Press the upper part of button
5
to
increase the selected
temperature. Press the lower part to decrease the temperature.
The desired temperature is indicated by the figures in icon no. 8
The remote control regulates the operation of the stove by
constantly comparing the room temperature (indicated at upper
right on the display and specifically the larger figures with the
cassette symbol near them) with the temperature set by the user.
Upon reaching the desired temperature in the room, the stove will
gradually go to minimum power. If instead the room temperature
drops below the set limit, the stove will gradually come back up to
maximum hearing performance.
Room temperature is measured by the remote control via a sensor
inside of it. Therefore, the stove will always attempt to reach the
temperature based on the measurements of the remote control
sensor.
Thanks to this characteristic, the remote control can be
considered a mobile external thermostat, with a range of
about 5 m (with batteries charged)
Since the remote control acts as an external thermostat,
it is necessary to for the remote control and the stove to
communicate with each other. It is therefore suggested
to keep it in the same room as the stove, within a radius
of 8 metres, but not so close that it will be affected by
the heat from the stove.
It is advisable to keep the remote control in the
room where the stove is installed so that the stove
and remote control can communicate with each
other.
If the remote control is moved out of range from
the stove, the stove will no longer have any
temperature feedback. It will therefore continue
operating in the same manner as was set by the
last transmission from the remote control.
Changing from automatic to manual mode
To change from
MANUAL
to
AUTOMATIC
mode, press button
4
so that the remote control display shows the message
MAN
and
the bars for the adjustment of flame power.
4.9.4.
Automatic mode with ECO-STOP
This mode changes stove operation in
automatic mode.
Upon
reaching the temperature set by the user, the stove goes to power
1 for a short period of time. Then, if the temperature remains
constant and above the set temperature, it shuts down. The stove
comes back on automatically only when the room requires heat
again, but not before a period of time has passed for the stove to
cool off. This option is advisable only if the stove works in highly
insulated rooms or where there is low heat dispersion over time.
Example of operation in ECOSTOP mode
If the room temperature detected by the sensor of the remote
control is 15°C and the set temperature is 20°C, the stove will
4