Chapter 4
INSTALLATION AND USE MANUAL
page
32
Operation
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
4.8.2.
Note on first ignition
The first attempt at ignition may not be successful,
since the feeder screw is empty and it is not always
able to fill the grate with required amount of pellets
in time to ensure normal ignition
CANCEL THE ALARM CONDITION FROM THE
EMERGENCY PANEL (see paragraph 4.16), REMOVE
PELLETS IN THE GRATE AND REPEAT LIGHTING
After repeated attempts at lighting, if there is no flame even though
pellets are flowing normally, check that the grate is correctly
positioned. It must be
placed where it adheres perfectly to its
housing and free of any ash incrustations
. If after this check no
abnormalities are found, it means that there may be a problem with the
stove components or that installation may not have been carried out
correctly.
REMOVE THE PELLETS FROM THE BURNER AND
CONTACT AN AUTHORISED MCZ TECHNICIAN.
4.8.3.
Start-up/shutdown from emergency panel
If the remote control is defective or the batteries are dead, you can
temporarily run the stove from the rear emergency panel.
In this configuration, the stove can operate only in manual mode and
with possibility to select from
3
levels of power.
•
LIGHTING THE STOVE WITHOUT THE REMOTE
CONTROL
To light the stove, place selector
“D”
to
ON.
At start-up the
red LED goes off and the green LED will start flashing until the
start-up phase is complete. At full operating power the green
LED will come on steady.
•
SELECTING POWER WITHOUT REMOTE CONTROL
You can choose from three levels of heating power:
MIN-MED-MAX
(selector
“E”
)
MINIMA
power is the 1st power;
MEDIUM
power is the 2nd power;
MAXIMUM
power is the 3rd power;
•
SHUTTING DOWN THE STOVE WITHOUT THE REMOTE
CONTROL
To shut down the stove, place selector
“D”
to
OFF.
Once the remote control is working again, remember
to put selector "D" back in the "REMOTE" position.
Otherwise the stove will disregard inputs from the
remote control.
- OFF
- REMOTE
- ON
- MIN
- MED
- MAX
D
E
- OFF
- REMOTE
- ON
- MIN
- MED
- MAX
TEST
- OFF
- REMOTE
- ON
- MIN
- MED
- MAX
TEST