Drive Status Indicators
Each drive carrier incorporates two LEDs, an upper (Green) and lower (Amber). In normal operation
the green indicator will be ON and will flicker as the drive operates. The amber indicator will only
be ON if there is a drive fault. If the green LED is OFF when the amber LED is ON, a power control
circuit failure is indicated.
Anti-tamper Locks
Anti-tamper locks are fitted in the drive carrier handles (Figure 22) and are accessed through the
small cutout in the latch section of the handle.These are provided to disable the normal ‘pinch‘ latch
action of the carrier handle.
Figure 22. Anti-tamper Lock
Dummy Carrier Modules
Dummy carrier modules are provided for fitting in all unused drive bays. They are designed as integral
drive module front caps and must be fitted to all unused drive bays to maintain a balanced airflow.
Blank Modules
When only one SR1202 RAID Controller Module is installed, a Blank module must be fitted in the
vacant RAID Controller Module slot at the rear of the enclosure to maintain airflow and ensure correct
operation.
!
WARNING
Operation of the Enclosure with ANY modules missing will disrupt the airflow and the drives will not
receive sufficient cooling. It is ESSENTIAL that all apertures are filled before operating the SR1202.