MAXDATA SR1202 M1 – Technical User Guide
Getting Started
34
35
MAXDATA SR1202 M1 – Technical User Guide
Getting Started
Activating the Locks
1. Carefully insert the lock key provided into the cutout in the handle.
2. Locate the key into its socket.
3. Rotate the key in a clockwise direction until the indicator is visible in the aperture beside the
key.
Figure 31. Activating the Anti-tamper Lock
4. Remove the key.
De-activation is the reverse of this procedure, that is:
• Rotate the key in an anti-clockwise direction until the indicator is no longer visible in the
aperture beside the key.
NOTE
A drive carrier cannot be installed if its anti-tamper lock is activated outside the Enclosure.
Power Cord Connection
Parts Check List
• Power cord to requisite local standards
Procedure
1. Attach the power cord to the Power Supply Modules,
2. Attach the power cord to the power distribution unit in the rack or other power source.
!
WARNING
Before applying power, carry out the grounding checks detailed in section “Grounding Checks” on
page 35.
3. A Power On LED on the Ops Panel indicates whether AC power is present.
!
CAUTION
The power connections must always be disconnected prior to removal of the Power Supply module
from the enclosure.