background image

21

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM
GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

MOTOR

ON-LINE

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 UL

ENTRAP

PHOTOCELL

CLOSE

COM

GA

TE DISABLE

PHOTOCE

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

SABLE

MA

GATE SP

N

CLA

MIN

ID

PLUG

ELL

24V

GND

24V Wire to Power Matrix 1

NO

 24V

to Matrix 1

Connect 24V power wire from the 

Primary/Single

 MAX MC-100 motor 

controller to power Matrix 1.

Connect (3) three RS-485 wires from 
the 

MAX MC-100 motor controller

 to 

the 

Matrix 1 -  PRIMARY GATE.

Connect (3) three RS-485 wires from the 
SECONDARY operator’s 

MAX MC-100 motor 

controller

 to the 

Matrix 1 - SEC GATE.

DO NOT 

connect

 PWR 24V.

Wiring operator

operators to matrix 1

Unscrew 

MAX MC-100 motor controller

 from operator 

to gain access to RS-485 connector. Schematics on page 
38 of manual shows where all plugs are located to 
re-install 

MAX MC-100 motor controller

.

1

1

5

V

AC

ON
PO

WE

R

OF

F

MA

X P

S-2

4

POWE

R S

UP

PL

Y

FU

SE
7 A

MP

IN

Ma

de

 in

 USA

POW

ER

IN

POW

ER/S

OL

AR

IN

BAT

TER

Y

IN

ww

w.m

ax.u

s.co

m

Mad

e in

 US

A

BAT

TER

Y

PAC

K

TO M

OTO

R

CON

TRO

LLE

R

E

1/2

Batter

y Volt

age

Re

plac

e

Ba

ttery

TES

T

Bat

tery PWR 

IN

Erro

r

F

MAX 

BC-7

Ba

tter

y Mo

dul

e

AL

ARM

PWR 24V -

GND -

RS-485 (

-) -

RS-485 (+) -

LIM

IT

SW

ITC

H

BAT

TER

Y

PA

CK

MOTO

R

INPUT

S

POWER IN

MO

TOR

www

.max.us.

co

m

Po

we

r

INP

UT

S

MC-

10

0

JO

G

RIGH

T

JOG

LE

FT

UL

En

tra

p

Mat

rix

On

 Li

ne

ER

D

Se

ns

itiv

ity

Pho

to

Ce

ll

Lim

it S

W

On

 Li

ne

Ed

ge

 2

Ed

ge

 1

Edge 1

Edge 2

Photo Cell

GND

Jog R

T

Jog L

T

M

OT

OR OV

ERL

OA

D

M

ot

or

 Co

ntroll

er

ERD

Min

Ma

x

Se

ns

itiv

ity

Primary/

Pri

ma

ry/

Single

Sin

gle

Operator

Op

era

tor

ALARM

PWR 24V -

GND -

RS-485 (-) -

RS-485 (+) -

LIMIT

SWITCH

BATTERY

PACK

MOTOR
INPUTS

POWER IN MOTOR

www.max.us.com

ALARM

PWR 24V -

GND -

RS-485 (-) -

RS-485 (+) -

LIMIT

SWITCH

BATTERY

PACK

MOTOR
INPUTS

POWER IN

MOTOR

www.max.us.com

22 AWG Min. 

5-conductor 

twisted pair, 

shielded cable

NOTE:

 Primary/Single operator 

closest to control box.

22 AWG Min. 3-conductor 

twisted pair, shielded cable

Primary/Single

Primary/Single

Operator

Operator

Secondary

Secondary

Operator

Operator

Bi-Parting Gates

Bi-Parting Gates

Control Box

Matrix 1

Primary/Single

Secondary

5 Wires to Matrix 1

3 Wires to Matrix 1

3 Wires to Matrix 1

5 Wires to Matrix 1

Summary of Contents for Phantom 2000

Page 1: ...MAX Phantom 2000 Installation and Owners Manual www max us com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA UL 325 Compliant...

Page 2: ......

Page 3: ...l Jog Switch to Operators Turn ON OFF Operator Power matrix 1 Matrix 1 Overview Wiring Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Ta...

Page 4: ...D Read the owner s manual Have a qualified service person make repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS UL 325 Clas...

Page 5: ...ed via supervision by security personnel The same type of device shall not be utilized for both the primary and the secondary entrapment protection means Use of a single device to cover both the openi...

Page 6: ...and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start H A minimum of two 2 WARNING SIGNS shall be installed one on...

Page 7: ...m accidentally opening and or closing on vehicles in the gate s path Entrapment Protection Photocell Helps guard against the opening gate from entrapment Closing Gate Protection Photocell Helps protec...

Page 8: ...www max us com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensit...

Page 9: ...CULAR traffic ONLY Pedestrians MUST use a separate entrance Install appropriate entrapment protection safety devices for the OPENING direction and CLOSING direction of gate cycling Install in ground S...

Page 10: ...o the GATE OPERATOR See page 14 CLOSING cycle protection device wires photocells to the CONTROL BOX See page 14 In ground loop wires to the CONTROL BOX See page 15 Conduit Guidelines and Suggestions S...

Page 11: ...on Photocell OPENING Cycle ONLY Photocell OPENING Cycle ONLY Sensing Edges Entrapment Area Entrapment Area Control Box RS 485 Jog Switch to Control Box Input Power Input Power Conduit REQUIRED Run AC...

Page 12: ...K TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge...

Page 13: ...230V AC ON P O W E R OF F M A X P S 2 4 PO W ER SU PP LY FU SE 7 AM P IN M a d e in U S A Select Input Voltage 115VAC or 230VAC disc on ne ct po wer be fore se rvicing un it W ARNIN G W ARNIN G HIGH...

Page 14: ...12 MAX Solar Panel Approx 45 solar installation Refer to Solar application guide...

Page 15: ...rance Moving Gate Can Cause Serious Injury or Death KEEP CLEAR Gate may move at any time without prior warning Do not let children operate the gate or play in the gate area This entrance is for vehicl...

Page 16: ...han 16 then secondary entrapment protection is REQUIRED in this area CLOSING Cycle NOTE Additional CLOSING Cycle Photocells can be installed anywhere needed Run all additional CLOSING Cycle photocell...

Page 17: ...sts per foot minimum inside conduit Safety Loops Are placed on each side of the gate to prevent the gate from closing on a vehicle in it s path They will stop or reverse the cycling of the gate while...

Page 18: ...ER LO AD M ot or Co nt ro lle r ER D M in M ax Se ns iti vit y W A R N I N G W A R N I N G c o n n e c t c h a s s is t o g r o u n d r o d f o r li g h t n in g p r o t e c t io n Check with local b...

Page 19: ...tage LEDs will light respectively PWR IN Error LED Lights when there is a battery connection problem Make sure battery plugs are correctly installed and there is no damaged or loose wires MOTOR OVERLO...

Page 20: ...t of the gate operator The ground point must be at an electrical panel a metallic cold water pipe that runs in the earth or a grounding rod Ground Rod within 10 ft of operator WARNING WARNING connect...

Page 21: ...R SOLAR IN Connector Included in kit Connect Input AC Power wire See page 18 for wiring At Gate Operator Wiring operator IMPORTANT MAX Magic Box and Gate Operator MUST EACH be Properly GROUNDED Proper...

Page 22: ...S O L A R I N B A T T E R Y I N w w w m a x u s c o m M a d e i n U S A B A T T E R Y P A C K T O M O T O R C O N T R O L L E R E 1 2 Battery Voltage Replace Battery ON OFF Battery TEST Battery Batter...

Page 23: ...RS 485 connector Schematics on page 38 of manual shows where all plugs are located to re install MAX MC 100 motor controller 115V AC ON PO W ER OF F M AX PS 2 4 PO W ER SU PP LY FU SE 7 AM P IN Ma de...

Page 24: ...00 Motor Controller Secondary MAX MC 100 Motor Controller Primary Single Open RIGHT OPEN RIGHT OPEN LEFT INSIDE Property PRIMARY SECONDARY OUTSIDE Property Jog Open Green Gnd Jog Close White INPUTS Ed...

Page 25: ...N GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MAX BC 7 Battery Module Wiring operator turn on off operator power Turn AC Power Switch ON A A B B C C D D E E F F G G H H I I J J K K To tur...

Page 26: ...fety Loop a closing gate will PAUSE if a second vehicle attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gat...

Page 27: ...itch Center Loop Safety Loop Safety Loop Exit Loop Gate Tamper See page 30 24V Power for Matrix 1 from Primary Single operator ONLY See pages 17 33 ID Plug See page 30 ID Plug Error LED See page 30 4...

Page 28: ...k up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPE...

Page 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Page 30: ...PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH...

Page 31: ...F F Med ium Low OF F ON Medium High OF F OF F High SW 4 SW 5 Ou tput B ON ON Pu lse on En try ON OF F B same as A OF F ON Pu lse on Exit OF F OF F Lo op Fa ult SW 3 ON Fail Se cure OF F Fa il Sa fe SW...

Page 32: ...authorization These will trigger the Gate Tamper relay MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE...

Page 33: ...a l P l a t e IMPORTANT Limit switches MUST be learned BEFORE Partial Open can be recorded To RECORD PARTIAL OPEN 1 With gate in CLOSED position press and release PARTIAL OPEN button to START recordin...

Page 34: ...tation or an additional External RESET Button to be connected Corresponding LEDs will light when each button is activated OPEN COM CLOSE GATE STATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Powe...

Page 35: ...r each gate operator s MC 100 Motor Controller that the Matrix 1 is successfully communicating with Connect 24VDC POWER from PRIMARY SINGLE operator ONLY See page 21 POWER LED Will light when 24V low...

Page 36: ...OPEN Limit switch contact point CLOSED Limit switch contact point IMPORTANT Manually Release arm and move the gate to the desired OPEN and CLOSED positions to adjust the limit tabs Make sure power is...

Page 37: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Page 38: ...on on control box NOTE When solid gates are installed in unusually high wind areas ERD sensor can be set to Min to keep the gate cycling normally in such extreme conditions CAUTION Minimum sensitivity...

Page 39: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Page 40: ...E ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTERY BACK UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF O...

Page 41: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Page 42: ...red CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the control box to shut off the alarm and reset the gate NOTE Alarm will automatically shut off after five minutes bu...

Page 43: ...t Clamp Assembly Operator cover with nameplate Swing arm T Bar Output collar and rings Output Shaft 7Ahr Battery Module Limit Switch Assembly Power Supply Assembly 900 1 Double Gear Box DC Brushless M...

Page 44: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...

Page 45: ...43...

Page 46: ...ls LLC 27211 Burbank Foothill Ranch Ca 92610 Tel 949 699 0220 www max us com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA UL 325 Compliant Max Phantom 2000...

Reviews: