14
Install photocells to help protect against entrapment during the
OPENING
cycle of the gate (secondary entrapment protection).
Install photocells to help protect vehicles during the
CLOSING
cycle of the gate.
Install sensing edge to help protect vehicles from a moving gate. See pages 17 & 25 for wiring instructions.
Beam Height:
21” Normal
27.5” Max.
Beam: 5” or LESS from CLOSED gate.
Photocell
(
OPENING
Cycle)
Photocell (
CLOSING
Cycle)
Photocell (
CLOSING
Cycle)
Photocell (
OPENING
Cycle)
Install just above gate operator.
Entrapment
Area
Gate Open
Gate Open
Gate Closed
Top View
Side View
If this dimension is less
than 16”, then secondary
entrapment protection is
REQUIRED
in this area.
CLOSING Cycle NOTE:
Additional
CLOSING
Cycle Photocells
can be installed anywhere needed. Run all additional CLOSING
Cycle photocell’s conduit to the
CONTROL BOX
.
OPENING Cycle NOTE:
Additional
OPENING
Cycle Photocells
can be installed anywhere needed. Run all additional
OPENING Cycle photocell’s conduit to the
GATE OPERATOR
.
Dual Gate Operators NOTE:
Run
EACH
OPENING
Cycle Photocells
conduit to each corresponding
GATE OPERATOR
. See page 9.
Run
OPENING
Cycle
photocell conduit to
GATE OPERATOR
.
Illustrations not to scale
installation
entrapment protection
Outside Property
Inside Property
Control Box
Control Box
Run
CLOSING
Cycle conduit to
CONTROL BOX
.
SENSING EDGE
Run wire to
GATE OPERATOR
.
SENSING EDGE
Mount on end of gate.
Conduit
Summary of Contents for Phantom 2000
Page 2: ......
Page 14: ...12 MAX Solar Panel Approx 45 solar installation Refer to Solar application guide...
Page 45: ...43...