background image

34

Open RIGHT

Power

INPUTS

MC-100

JOG

RIGHT

JOG

LEFT

UL

Entrap

Matrix

On Line

ERD

Sensitivity

Photo

Cell

Limit SW

On Line

Edge 2

Edge 1

Edge 1

Edge 2

Photo Cell

GND

Jog R

T

Jog L

T

MOTOR OVERLOAD

Motor Controller

ERD

Min

Max

Sensitivity

1

1

5

V

AC

ON

POW

ER

OF

F

MA

X P

S-24

PO

WE

R SUPPL

Y

FUSE

7 AM

P

IN

Ma

de

 in

 USA

POWE

R

IN

PO

WER

/SO

LAR

IN

BA

TTER

Y

IN

www

.m

ax.u

s.co

m

Ma

de in

 US

A

BA

TTE

RY

PAC

K

TO MOT

OR

CON

TRO

LLE

R

E

1/2

Ba

tter

y Voltage

Repl

ace

Batter

y

TEST

Batt

ery

ON/OF

F

Batt

ery

PWR 

IN

Error

F

MAX BC-7

Batt

ery Mo

dul

e

Po

wer

INP

UT

S

MC

-10

0

JOG

RIGH

T

JOG

LE

FT

UL

En

tra

p

Ma

trix

On 

Lin

e

ER

D

Se

ns

itiv

ity

Ph

oto

Ce

ll

Limi

t S

W

On

 Li

ne

Ed

ge

 2

Ed

ge

 1

Edg

e 1

Ed

ge

 2

Ph

oto

Ce

ll

GN

D

Jo

g R

T

Jo

g LT

M

OT

OR

 OVE

RLOAD

M

oto

r C

on

tro

lle

r

ERD

Mi

n

Ma

x

The limit tabs need to be set 

BEFORE

 the gate can be cycled or 

DAMAGE

 could occur. 

Approximate OPEN and CLOSED 

limit tab positions.

OPEN

 LED

OPEN

 LED

CLOSED

 Tab

Activated

Position

CLOSED

 Tab

Activated
Position

OPEN

 Tab

Activated

Position

OPEN

 Tab

Activated
Position

Push and 

HOLD

 the 

JOG LEFT

 or 

JOG RIGHT

 

buttons accordingly on the 

MAX MC-100 motor 

controller

 to move the gate (release the button to 

stop gate). This allows gate to be moved back and 
fourth without leaving the operator to “fine tune” 
the open and close gate positions if desired.

Adjustments

open and close limits

CLO

SED

LIM

IT

OPEN

LIMIT

Limit

Switch Box

OPEN

 Limit 

switch contact 
point.

CLOSED

 Limit 

switch contact 
point.

IMPORTANT: 

Manually Release

 arm and move the 

gate to the desired 

OPEN

 and 

CLOSED

 positions to 

adjust the limit tabs. Make sure power is 

ON

.

Arm

 Opening Direc

tio

n

Arm

 Opening Direc

tio

n

Arm Closed Position

Arm Closed Position

Arm Open Position

Arm Open Position

Open 

Limit Switch

Closed 

Limit Switch

CLOSED

 LED

CLOSED

 LED

Open LEFT

R

ot

at

e

 L

im

it

 T

a

b

 

u

nt

il 

LE

D

 li

gh

ts

CLOSED

LIMIT

OPEN
LIMIT

Arm in CLOSED

position

Operator

Opens RIGHT

ADJUST LIMITS:

CLOSED

LOSE

LOSE

LIMIT

LIMIT

LIMIT

LIMIT

LIMIT

LIMIT

LIMIT

LED

lights

Limit
Tab Screw

1.

 Move gate to 

OPEN

 position.

2.

 Loosen open limit tab screw.

3.

 Rotate open limit tab until open 

 LED 

lights.

4.

 Tighten open limit tab screw.

5.

 Move gate to 

CLOSED

 position.

6.

 Loosen closed limit tab screw.

7.

 Rotate closed limit tab until closed 

 LED 

lights.

8.

 Tighten closed limit tab screw. 

Cycle the gate 

OPEN

 and 

CLOSED

 after the limit 

tabs have been set 

AND

 the arm is 

SECURE

Operator will cycle slowly to 

LEARN

 the 

open

 and 

closed

 gate positions. After the operator learns 

the gate positions, it will cycle at the 

GATE SPEED

 

selected for normal operation.

Manually Release Arm

“Fine Tune” Limits Adjustment

IMPORTANT:

 

Manually Secure Arm (see page 35)

IMPORTANT:

 LEDs 

MUST

 light up when gate 

reaches 

OPEN

 and 

CLOSE

 positions or operator 

WILL NOT

 learn gate positions. If gate positions 

are not learned, gate cycling speed will 

remain

 

slow during normal operation.

EXAMPLE:

LED Indicators

IMPORTANT:

 

Remove breather 
pin from gear 
reducer 

BEFORE

 

cycling operator.

WARNING:

 Avoid moving arm while “Fine Tune” adjusting.

Breather Pin

CAUTI

ON

REMOVE

BEFORE

OPERA

TIO

N

Summary of Contents for Phantom 2000

Page 1: ...MAX Phantom 2000 Installation and Owners Manual www max us com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA UL 325 Compliant...

Page 2: ......

Page 3: ...l Jog Switch to Operators Turn ON OFF Operator Power matrix 1 Matrix 1 Overview Wiring Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Ta...

Page 4: ...D Read the owner s manual Have a qualified service person make repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS UL 325 Clas...

Page 5: ...ed via supervision by security personnel The same type of device shall not be utilized for both the primary and the secondary entrapment protection means Use of a single device to cover both the openi...

Page 6: ...and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start H A minimum of two 2 WARNING SIGNS shall be installed one on...

Page 7: ...m accidentally opening and or closing on vehicles in the gate s path Entrapment Protection Photocell Helps guard against the opening gate from entrapment Closing Gate Protection Photocell Helps protec...

Page 8: ...www max us com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensit...

Page 9: ...CULAR traffic ONLY Pedestrians MUST use a separate entrance Install appropriate entrapment protection safety devices for the OPENING direction and CLOSING direction of gate cycling Install in ground S...

Page 10: ...o the GATE OPERATOR See page 14 CLOSING cycle protection device wires photocells to the CONTROL BOX See page 14 In ground loop wires to the CONTROL BOX See page 15 Conduit Guidelines and Suggestions S...

Page 11: ...on Photocell OPENING Cycle ONLY Photocell OPENING Cycle ONLY Sensing Edges Entrapment Area Entrapment Area Control Box RS 485 Jog Switch to Control Box Input Power Input Power Conduit REQUIRED Run AC...

Page 12: ...K TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge...

Page 13: ...230V AC ON P O W E R OF F M A X P S 2 4 PO W ER SU PP LY FU SE 7 AM P IN M a d e in U S A Select Input Voltage 115VAC or 230VAC disc on ne ct po wer be fore se rvicing un it W ARNIN G W ARNIN G HIGH...

Page 14: ...12 MAX Solar Panel Approx 45 solar installation Refer to Solar application guide...

Page 15: ...rance Moving Gate Can Cause Serious Injury or Death KEEP CLEAR Gate may move at any time without prior warning Do not let children operate the gate or play in the gate area This entrance is for vehicl...

Page 16: ...han 16 then secondary entrapment protection is REQUIRED in this area CLOSING Cycle NOTE Additional CLOSING Cycle Photocells can be installed anywhere needed Run all additional CLOSING Cycle photocell...

Page 17: ...sts per foot minimum inside conduit Safety Loops Are placed on each side of the gate to prevent the gate from closing on a vehicle in it s path They will stop or reverse the cycling of the gate while...

Page 18: ...ER LO AD M ot or Co nt ro lle r ER D M in M ax Se ns iti vit y W A R N I N G W A R N I N G c o n n e c t c h a s s is t o g r o u n d r o d f o r li g h t n in g p r o t e c t io n Check with local b...

Page 19: ...tage LEDs will light respectively PWR IN Error LED Lights when there is a battery connection problem Make sure battery plugs are correctly installed and there is no damaged or loose wires MOTOR OVERLO...

Page 20: ...t of the gate operator The ground point must be at an electrical panel a metallic cold water pipe that runs in the earth or a grounding rod Ground Rod within 10 ft of operator WARNING WARNING connect...

Page 21: ...R SOLAR IN Connector Included in kit Connect Input AC Power wire See page 18 for wiring At Gate Operator Wiring operator IMPORTANT MAX Magic Box and Gate Operator MUST EACH be Properly GROUNDED Proper...

Page 22: ...S O L A R I N B A T T E R Y I N w w w m a x u s c o m M a d e i n U S A B A T T E R Y P A C K T O M O T O R C O N T R O L L E R E 1 2 Battery Voltage Replace Battery ON OFF Battery TEST Battery Batter...

Page 23: ...RS 485 connector Schematics on page 38 of manual shows where all plugs are located to re install MAX MC 100 motor controller 115V AC ON PO W ER OF F M AX PS 2 4 PO W ER SU PP LY FU SE 7 AM P IN Ma de...

Page 24: ...00 Motor Controller Secondary MAX MC 100 Motor Controller Primary Single Open RIGHT OPEN RIGHT OPEN LEFT INSIDE Property PRIMARY SECONDARY OUTSIDE Property Jog Open Green Gnd Jog Close White INPUTS Ed...

Page 25: ...N GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MAX BC 7 Battery Module Wiring operator turn on off operator power Turn AC Power Switch ON A A B B C C D D E E F F G G H H I I J J K K To tur...

Page 26: ...fety Loop a closing gate will PAUSE if a second vehicle attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gat...

Page 27: ...itch Center Loop Safety Loop Safety Loop Exit Loop Gate Tamper See page 30 24V Power for Matrix 1 from Primary Single operator ONLY See pages 17 33 ID Plug See page 30 ID Plug Error LED See page 30 4...

Page 28: ...k up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPE...

Page 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Page 30: ...PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH...

Page 31: ...F F Med ium Low OF F ON Medium High OF F OF F High SW 4 SW 5 Ou tput B ON ON Pu lse on En try ON OF F B same as A OF F ON Pu lse on Exit OF F OF F Lo op Fa ult SW 3 ON Fail Se cure OF F Fa il Sa fe SW...

Page 32: ...authorization These will trigger the Gate Tamper relay MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE...

Page 33: ...a l P l a t e IMPORTANT Limit switches MUST be learned BEFORE Partial Open can be recorded To RECORD PARTIAL OPEN 1 With gate in CLOSED position press and release PARTIAL OPEN button to START recordin...

Page 34: ...tation or an additional External RESET Button to be connected Corresponding LEDs will light when each button is activated OPEN COM CLOSE GATE STATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Powe...

Page 35: ...r each gate operator s MC 100 Motor Controller that the Matrix 1 is successfully communicating with Connect 24VDC POWER from PRIMARY SINGLE operator ONLY See page 21 POWER LED Will light when 24V low...

Page 36: ...OPEN Limit switch contact point CLOSED Limit switch contact point IMPORTANT Manually Release arm and move the gate to the desired OPEN and CLOSED positions to adjust the limit tabs Make sure power is...

Page 37: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Page 38: ...on on control box NOTE When solid gates are installed in unusually high wind areas ERD sensor can be set to Min to keep the gate cycling normally in such extreme conditions CAUTION Minimum sensitivity...

Page 39: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Page 40: ...E ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTERY BACK UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF O...

Page 41: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Page 42: ...red CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the control box to shut off the alarm and reset the gate NOTE Alarm will automatically shut off after five minutes bu...

Page 43: ...t Clamp Assembly Operator cover with nameplate Swing arm T Bar Output collar and rings Output Shaft 7Ahr Battery Module Limit Switch Assembly Power Supply Assembly 900 1 Double Gear Box DC Brushless M...

Page 44: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...

Page 45: ...43...

Page 46: ...ls LLC 27211 Burbank Foothill Ranch Ca 92610 Tel 949 699 0220 www max us com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA UL 325 Compliant Max Phantom 2000...

Reviews: