background image

17

POWE

R

IN

POWER

/SOLAR

IN

BA

TTER

Y

IN

www

.max.us.com

Ma

de in 

USA

BA

TTER

Y

PACK

TO MOTOR

CO

NTROLLER

E

1/2

Batter

y Vo

ltage

Replac

e

Batter

y

ON/OFF
Batte

ry

TES

T

Batte

ry

Batte

ry IN

Error

F

MAX BC-7

Batter

y Modul

e

IMPORT

ANT

connect to

“BA

TT

ER

Y IN”

before use

ALARM

PWR 24V -

GND -

RS-485 (-) -

RS-485 (+) -

LIMIT

SWITCH

BATTERY

PACK

MOTOR
INPUTS

POWER IN

MOTOR

www.max.us.com

Power

INPUTS

MC-100

JOG

RIGHT

JOG

LEFT

UL

Entrap

Matrix

On Line

ERD

Sensitivity

Photo

Cell

Limit SW

On Line

Edge 2

Edge 1

Edge 1

Edge 2

Photo Cell

GND

Jog R

T

Jog L

T

MOTOR OVERLOAD

Motor Controller

ERD

Min

Max

Sensitivity

Wiring operator

3

4

5

6

7

1

1

2

3

4

5

6

7

A

B

C

D

E

F

G

H

I

J

K

L

M

A

B

C

D

E

F

G

I

K

H

J

L

M

2

BATTERY Plug:

 

MUST

 be plugged into 

BATTERY IN 

port 

Before

 use.

POWER/SOLAR IN Port:

 MAX PS-24 Power Supply connection.

Battery Voltage LEDs: 

Show amount of battery power available.

LEDs are always ON when using AC power. Test battery button must be 
pressed to show battery power when using battery power ONLY.

ON/OFF Battery Button:

IMPORTANT:

 Battery power 

automatically

 turns 

ON

 when MAX PS-24 Power 

Supply 

AC POWER

 

Switch

 is turned 

ON

.

To turn OFF 

ALL POWER

 to operator:

1.

 Turn OFF 

AC POWER Switch 

on MAX PS-24 Power Supply.

 Battery 

power 

remains ON

.

2.

 

WAIT

 for 15 seconds.

3. Press and HOLD 

(approx. 5 seconds) the 

YELLOW

 

ON/OFF BATTERY

 

  button until MAX BC-7 LEDs turn 

ON

, then release button.

  LEDs will turn 

OFF

.

Replace Battery LED: 

Replace battery when lit.

TEST Battery Button: 

Press to show amount of battery power available when 

using battery power ONLY (Battery voltage LEDs will light respectively).

PWR IN Error LED: 

Lights when there is a battery connection problem. Make 

sure battery plugs are correctly installed and there is no damaged or loose 
wires.

MOTOR OVERLOAD LED:

 Excessive current being drawn by motor when lit.

ERD LED:

 ERD sensor has been activated when lit.

ERD Sensitivity Knob: 

Changes sensitivity of ERD sensor.

ERD Sensitivity LED: 

MAX sensitivity reached when lit.

Jog LEFT/RIGHT Buttons:

Push and 

HOLD

 buttons accordingly to move the gate (release the button to 

stop gate). 

WARNING:

 Avoid moving arm while using Jog buttons.

INPUTS:

Jog LT/RT: 

Connects to External Jog switch on Control Box.

GND: 

Low Voltage Common connection.

Edge 1: 

Connects to a Sensing Edge. Multiple sensing edges can be 

connected.

Edge 2: 

Connects to a second Sensing Edge. Multiple sensing edges can be 

connected.

PHOTOCELL: 

Connects to a UL 325 Standard 

OPENING Cycle

 photocell 

ONLY

. Multiple 

OPENING Cycle

 photocells can be connected.

Matrix On Line LED: 

Gate operator is successfully communicating with 

Matrix 1 when lit.

Limit SW On Line LED: 

Limit Switch Box is successfully communicating 

with MC-100 Motor Controller when lit.

Edge 1 LED: 

Reversing Edge 1 input has been activated when lit.

Edge 2 LED: 

Reversing Edge 2 input has been activated when lit.

UL Entrap LED:

 Edge1/Edge2/Photocell input has been activated when lit.

Photocell LED:

 Photocell input has been activated when lit.

Power LED: 

Low voltage power is connected when lit.

OPENING

 Cycle

Photocells

ONLY.

24V ONLY

Photocell

Power.

Photocell (N.O.)

Edge 1

(N.O.)

Edge 2

(N.O.)

GND

GND

GND

24V

24V

RS-485

GND

External

Jog Switch

Sensing Edges

To Matrix 1

Gate Operator System Overview continued

MAX MC-100 Motor Controller

MAX BC-7 Battery Module

DUAL GATE OPERATORS NOTE:

 Connect 

EACH

 photocell/reverse 

edge to the 

corresponding gate operator

. See page 9.

Summary of Contents for Phantom 2000

Page 1: ...MAX Phantom 2000 Installation and Owners Manual www max us com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA UL 325 Compliant...

Page 2: ......

Page 3: ...l Jog Switch to Operators Turn ON OFF Operator Power matrix 1 Matrix 1 Overview Wiring Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Ta...

Page 4: ...D Read the owner s manual Have a qualified service person make repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS UL 325 Clas...

Page 5: ...ed via supervision by security personnel The same type of device shall not be utilized for both the primary and the secondary entrapment protection means Use of a single device to cover both the openi...

Page 6: ...and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start H A minimum of two 2 WARNING SIGNS shall be installed one on...

Page 7: ...m accidentally opening and or closing on vehicles in the gate s path Entrapment Protection Photocell Helps guard against the opening gate from entrapment Closing Gate Protection Photocell Helps protec...

Page 8: ...www max us com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensit...

Page 9: ...CULAR traffic ONLY Pedestrians MUST use a separate entrance Install appropriate entrapment protection safety devices for the OPENING direction and CLOSING direction of gate cycling Install in ground S...

Page 10: ...o the GATE OPERATOR See page 14 CLOSING cycle protection device wires photocells to the CONTROL BOX See page 14 In ground loop wires to the CONTROL BOX See page 15 Conduit Guidelines and Suggestions S...

Page 11: ...on Photocell OPENING Cycle ONLY Photocell OPENING Cycle ONLY Sensing Edges Entrapment Area Entrapment Area Control Box RS 485 Jog Switch to Control Box Input Power Input Power Conduit REQUIRED Run AC...

Page 12: ...K TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge...

Page 13: ...230V AC ON P O W E R OF F M A X P S 2 4 PO W ER SU PP LY FU SE 7 AM P IN M a d e in U S A Select Input Voltage 115VAC or 230VAC disc on ne ct po wer be fore se rvicing un it W ARNIN G W ARNIN G HIGH...

Page 14: ...12 MAX Solar Panel Approx 45 solar installation Refer to Solar application guide...

Page 15: ...rance Moving Gate Can Cause Serious Injury or Death KEEP CLEAR Gate may move at any time without prior warning Do not let children operate the gate or play in the gate area This entrance is for vehicl...

Page 16: ...han 16 then secondary entrapment protection is REQUIRED in this area CLOSING Cycle NOTE Additional CLOSING Cycle Photocells can be installed anywhere needed Run all additional CLOSING Cycle photocell...

Page 17: ...sts per foot minimum inside conduit Safety Loops Are placed on each side of the gate to prevent the gate from closing on a vehicle in it s path They will stop or reverse the cycling of the gate while...

Page 18: ...ER LO AD M ot or Co nt ro lle r ER D M in M ax Se ns iti vit y W A R N I N G W A R N I N G c o n n e c t c h a s s is t o g r o u n d r o d f o r li g h t n in g p r o t e c t io n Check with local b...

Page 19: ...tage LEDs will light respectively PWR IN Error LED Lights when there is a battery connection problem Make sure battery plugs are correctly installed and there is no damaged or loose wires MOTOR OVERLO...

Page 20: ...t of the gate operator The ground point must be at an electrical panel a metallic cold water pipe that runs in the earth or a grounding rod Ground Rod within 10 ft of operator WARNING WARNING connect...

Page 21: ...R SOLAR IN Connector Included in kit Connect Input AC Power wire See page 18 for wiring At Gate Operator Wiring operator IMPORTANT MAX Magic Box and Gate Operator MUST EACH be Properly GROUNDED Proper...

Page 22: ...S O L A R I N B A T T E R Y I N w w w m a x u s c o m M a d e i n U S A B A T T E R Y P A C K T O M O T O R C O N T R O L L E R E 1 2 Battery Voltage Replace Battery ON OFF Battery TEST Battery Batter...

Page 23: ...RS 485 connector Schematics on page 38 of manual shows where all plugs are located to re install MAX MC 100 motor controller 115V AC ON PO W ER OF F M AX PS 2 4 PO W ER SU PP LY FU SE 7 AM P IN Ma de...

Page 24: ...00 Motor Controller Secondary MAX MC 100 Motor Controller Primary Single Open RIGHT OPEN RIGHT OPEN LEFT INSIDE Property PRIMARY SECONDARY OUTSIDE Property Jog Open Green Gnd Jog Close White INPUTS Ed...

Page 25: ...N GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MAX BC 7 Battery Module Wiring operator turn on off operator power Turn AC Power Switch ON A A B B C C D D E E F F G G H H I I J J K K To tur...

Page 26: ...fety Loop a closing gate will PAUSE if a second vehicle attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gat...

Page 27: ...itch Center Loop Safety Loop Safety Loop Exit Loop Gate Tamper See page 30 24V Power for Matrix 1 from Primary Single operator ONLY See pages 17 33 ID Plug See page 30 ID Plug Error LED See page 30 4...

Page 28: ...k up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPE...

Page 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Page 30: ...PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH...

Page 31: ...F F Med ium Low OF F ON Medium High OF F OF F High SW 4 SW 5 Ou tput B ON ON Pu lse on En try ON OF F B same as A OF F ON Pu lse on Exit OF F OF F Lo op Fa ult SW 3 ON Fail Se cure OF F Fa il Sa fe SW...

Page 32: ...authorization These will trigger the Gate Tamper relay MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE...

Page 33: ...a l P l a t e IMPORTANT Limit switches MUST be learned BEFORE Partial Open can be recorded To RECORD PARTIAL OPEN 1 With gate in CLOSED position press and release PARTIAL OPEN button to START recordin...

Page 34: ...tation or an additional External RESET Button to be connected Corresponding LEDs will light when each button is activated OPEN COM CLOSE GATE STATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Powe...

Page 35: ...r each gate operator s MC 100 Motor Controller that the Matrix 1 is successfully communicating with Connect 24VDC POWER from PRIMARY SINGLE operator ONLY See page 21 POWER LED Will light when 24V low...

Page 36: ...OPEN Limit switch contact point CLOSED Limit switch contact point IMPORTANT Manually Release arm and move the gate to the desired OPEN and CLOSED positions to adjust the limit tabs Make sure power is...

Page 37: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Page 38: ...on on control box NOTE When solid gates are installed in unusually high wind areas ERD sensor can be set to Min to keep the gate cycling normally in such extreme conditions CAUTION Minimum sensitivity...

Page 39: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Page 40: ...E ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTERY BACK UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF O...

Page 41: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Page 42: ...red CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the control box to shut off the alarm and reset the gate NOTE Alarm will automatically shut off after five minutes bu...

Page 43: ...t Clamp Assembly Operator cover with nameplate Swing arm T Bar Output collar and rings Output Shaft 7Ahr Battery Module Limit Switch Assembly Power Supply Assembly 900 1 Double Gear Box DC Brushless M...

Page 44: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...