Use following command to assign same CDC Timer to all CDC tables:
4914-*-CDC Timer
Use following command to assign Allowed List to a table:
4915-1-CDC Table-Allowed List
Where,
CDC Table is from 0 to 3.
Allowed List is from 0 to 7.
Use following command to assign same Allowed List to all the tables:
4915-*-Allowed List
Use following command to assign Denied List to a table:
4916-1-CDC Table-Denied List
Where,
CDC Table is from 0 to 3.
Denied List is from 0 to 7.
Use following command to assign same Denied List to all the tables:
4916-*-Denied List
Step 4
Go to step 2 above.
Step 5
Use following command to default a CDC table:
4901-1-CDC Table-#
Where,
CDC Table is from 0 to 3.
Use following command to default all the CDC Tables:
4901-*-#
Default CDC tables are given as below:
CDC Table Meaning
0
CDC OFF for all calls
1
CDC ON for Outgoing STD and ISD calls
2
CDC ON for Outgoing 95, 98, STD and ISD calls
3
CDC ON for all Outgoing calls
Step 6
To know programming details, please refer “Configuration Reports”.
Example 1:
Program station 21 (software port number 00) for following constraints:
Disconnect all calls after 180 seconds.
Solution:
• Assign default CDC table 3 to station 21.
4920-1-00-3
• Since default CDC Timer is 160 seconds and 20 seconds are adds as warning time the calls will get
disconnected after 180 seconds. Hence no programming is required.